1 . Error Display and How to Take a Measure
235
MF-C2000A Series
Chapter 2 Inspection and Measure T
o Be T
aken at Occurrence of an Error
Introduction Part
Operating Part
Maintenance Part
Appendixes
Installation
and
Preparation
Part
No .
Contents of error
LD
Alarm
output
Measures
035
LASER POWER OUT OF RANGE
-
-
The monitor value of laser energy is out of the
range of "HIGH" and "LOW" set on the MONITOR
screen. → P.91, P.133, P.136, P.137, and P.155
Check "HIGH" and "LOW" settings. If monitored
value is abnormal, consult us.
037
VIBRATION DETECTED
OFF
ON
Shock and vibration has been detected.
Check around any other trouble. After checking that
nothing is damaged, press the RESET button.
042
COOLER ERROR
OFF
ON
An error has occurred with the FA cooler unit on the
rear.
Check Error No. on the FA cooler and see the oper-
ation manual for ENC-GR500L-Pro on the Apiste’s
homepage.
043
HEAT DETECTOR ERROR
OFF
ON
The communication line between the heat detector
and the laser equipment is abnormal. → P.65
Check the connector.
The voltage of the heat detector may be low. Check
the connector, and if the trouble will continue even
after the RESET button is pressed, consult us.
046
047
049
FIBER ERROR1
FIBER ERROR2
FIBER ERROR3
OFF
ON
Breakage of an optical fiber has been detected.
Check that the optical fiber is connected
048
HEAT DETECTOR TEMP. READ
ERROR
ON
ON
An error has occurred when reading the tempera-
ture of the heat detector.
Check the connector. The cable between the heat
detector and the laser equipment may be discon-
nected.
060
POWER FPGA ERROR1
OFF
ON
An error has occurred with the controller unit.
Consult us.
061
POWER FPGA CALC. ERROR
OFF
ON
An error has occurred with the controller unit.
Consult us.
063
064
POWER FPGA ERROR 2
POWER FPGA ERROR 3
OFF
ON
An error has occurred with the controller unit.
Consult us.
067
INTERNAL RS-232C ERROR
OFF
ON
The communication line in the main unit is abnor-
mal.
If there is any noise generation source nearby,
separate it as far as possible or take a preventive
measure for occurrence of noise.
068
INTERNAL RS-232C TIMEOUT
OFF
ON
The communication line in the main unit is abnor-
mal.
If there is any noise generation source nearby,
separate it as far as possible or take a preventive
measure for occurrence of noise.
069
PANEL 485COMM TIMEOUT
OFF
ON
The communication line in the main unit is abnor-
mal.
If there is any noise generation source nearby,
separate it as far as possible or take a preventive
measure for occurrence of noise.
Содержание MF-C2000A Series
Страница 1: ...AA04OM1209213 07 FIBER LASER WELDER MF C2000A Series OPERATION MANUAL ...
Страница 21: ...Introduction Part ...
Страница 22: ......
Страница 34: ......
Страница 42: ......
Страница 43: ...Installation and Preparation Part ...
Страница 44: ......
Страница 73: ...Operating Part ...
Страница 74: ......
Страница 78: ......
Страница 142: ......
Страница 208: ...208 MF C2000A Series 4 Connector Functions REM I L Connector E STOP Connector Refer to the Operating Part Chapter 4 ...
Страница 212: ......
Страница 213: ...Maintenance Part ...
Страница 214: ......
Страница 232: ......
Страница 244: ......
Страница 245: ...Appendixes ...
Страница 246: ......