186
MF-C2000A Series
4 . Commands
Pulse width
Measurement interval
0.50 to 0.90 ms
0.01 ms
0.95 to 1.80 ms
0.02 ms
1.85 to 4.50 ms
0.05 ms
4.55 to 9.00 ms
0.1 ms
9.05 to 18.00 ms
0.2 ms
18.05 to 45.00 ms
0.5 ms
45.05 to 90.00 ms
1.0 ms
90.05 to 180.00 ms
2.0 ms
180.05 to 450.00 ms
5.0 ms
450.05 to 900.00 ms
10.0 ms
⇒
Since the number of data to be sent each time is limited to 5, it is necessary to
change the classification No. according to the "number of waveform data of the
laser power monitor" sent by "R00 nn 04" to perform repeated reading.
51 LD Output Total Time
Data No .
Item
Data Range
01*
[FLASH WORK TIME] on the [STATUS] screen
0000000 – 9999999 (×0.1H)
40 Backup Memory Settings
Data No .
Item
Data Range
01*
[NETWORK #] on the [CONFIG] screen
00 – 15
02*
[IP ADDRESS] on the [CONFIG] screen
000000000000 – 999999999999
03*
[SUBNET MASK] on the [CONFIG] screen
000000000000 – 999999999999
04*
[DEFAULT GATEWAY] on the [CONFIG] screen
000000000000 – 999999999999
05*
Unused
Fixed to 00
06*
Unused
Fixed to 000
07*
Unused
Fixed to 0
08*
Unused
Fixed to 00000000
09*
Unused
Fixed to 00000000
10*
Unused
Fixed to 00000000
11*
Unused
Fixed to 00000000
12*
Unused
Fixed to 00000000
13*
Unused
Fixed to 00000000
Содержание MF-C2000A Series
Страница 1: ...AA04OM1209213 07 FIBER LASER WELDER MF C2000A Series OPERATION MANUAL ...
Страница 21: ...Introduction Part ...
Страница 22: ......
Страница 34: ......
Страница 42: ......
Страница 43: ...Installation and Preparation Part ...
Страница 44: ......
Страница 73: ...Operating Part ...
Страница 74: ......
Страница 78: ......
Страница 142: ......
Страница 208: ...208 MF C2000A Series 4 Connector Functions REM I L Connector E STOP Connector Refer to the Operating Part Chapter 4 ...
Страница 212: ......
Страница 213: ...Maintenance Part ...
Страница 214: ......
Страница 232: ......
Страница 244: ......
Страница 245: ...Appendixes ...
Страница 246: ......