12. Troubleshooting
12-4
⑪
E11
Message
CYCLE TROUBLE
Time of
detection
During the welding sequence.
Cause of fault
The start signal is turned off during welding when SM is set to 0 on
the SET2 #1 screen.
Measures
Turn on [ERR RESET].
Output signal
Outputs the trouble [NG] signal or the caution [CAUTION] signal
when the fault occurs.
⑫
E12
Message
SCR SHORT
Time of
detection
During the squeeze.
Cause of fault
The thyristor short-circuit current is detected during the squeeze.
Note: The short-circuit current is not detected when the toroidal coil is
not connected to the
MEA-100B
.
Measures
The thyristor may be broken. Contact us or your distributor for repairs.
Output signal
Outputs the trouble [NG] signal when the fault occurs.
⑬
E13
Message
MEMORY TROUBLE
Time of
detection
When the power is turned on.
Cause of fault
An error is found in the schedule or other settings.
Measures
Turn on [ERR RESET] and then check the schedule and other
settings. Correct settings.
Output signal
Outputs the trouble [NG] signal when the error arises.
⑭
E14
Message
CURRENT SETTING ERR
Time of
detection
When the start signal is input.
Cause of fault
The current exceeding the maximum current is tried to be set during
operation with the secondary constant-current control.
Note: This error does not occur when the power supply voltage
fluctuation compensation control is selected.
Measures
Edit the current setting so that it falls within the setting range (less
than the maximum current).
Output signal
Outputs the trouble [NG] signal when the error arises.
⑮
E15
Message
WELD ABORT
Time of
detection
During the welding sequence.
Cause of fault
The [WELD STOP] signal is turned off.
Measures
Input the [WELD STOP] signal and turn on [ERR RESET].
Output signal
Outputs the trouble [NG] signal when the fault occurs.