MEA-100B
10. Interface
10-4
Terminal No.
Description
13-14
[END]
Output terminal for End [END] signal.
The signal is output upon completion of the welding sequence.
Note: For timing details, see
11. Timing Chart
.
Relay contact output: 24 V DC, or 250 V AC or less, 0.5 A
15-16
[NG]
Output terminal for trouble [NG] signal.
The circuit is opened when a trouble occurs.
(Preset the fault signal attribute so that the trouble signal can be output
when the fault occurs. For details, see 9. (2)
.)
The circuit is closed when [ERR RESET] is input.
Note: When the power supply of the
MEA-100B
is off, the circuit is
opened.
Relay contact output: 24 V DC, or 250 V AC or less, 0.5 A
17-18
[GOOD]
Output terminal for Normal End [GOOD] signal.
The circuit is closed if the current falls within the monitor range, or if the
current monitor function is not used after the welding sequence has
been completed.
Relay contact output: 24 V DC, or 250 V AC or less, 0.5 A
19
[COM]
Common terminal for input.
20
[WELD
SKIP]
Input terminal for [WELD SKIP] signal.
If this circuit is closed, the stage within the welding sequence are
skipped.
The specific operation depends on the weld skip (WS) setting, as shown
below:
WS: 0
→
Skips to the next stage of the sequence.
(If WELD1 is underway, skips to COOL. If WELD2 is
underway, skips to HOLD.)
WS: 1
→
Skips to HOLD.
21
[WELD
STOP]
Input terminal for [STOP] signal.
If this circuit is opened, the welding sequence including the welding
operation is immediately halted.
[E15: WELD ABORT] is given if the circuit is open during welding or
when the start signal is input. (See
12. Troubleshooting
.)
22
[CNTR
RESET]
Input terminal for Counter Reset [CNTR RESET] signal.
If this circuit is closed, the total count is reset.
23
[ERR
RESET]
Input terminal for trouble reset [ERR RESET] signal.
Closing this circuit clears [NG] and [CAUTION] outputs. Note that the
outputs are cleared only if the cause of the original fault has been
rectified.
24
[STEP
RESET]
Input terminal for [STEP RESET] signal.
Closing this circuit resets the stepper number and the stepper count.
25
[COM]
Common terminal for input signals.
26
[WELD
ON/OFF]
Input terminal for [WELD ON/OFF] signal.
Opened
→ WELD OFF (Shuts
off the welding current.)
Closed
→ W
ELD ON (Flows the welding current.)
For the welding current to flow, the [WELD] key on the front panel must
also be ON.