MEA-100B
9. Detail Settings (SET2 Screen)
9-2
Display
Function
Setting
Initial
Setting
c
SS
Selects a setting
method of the
schedule number
0: 31 schedules from the input
terminal without parity
1: 31 schedules from the input
terminal with parity
2: 5 schedules from the input terminal
3: 31 schedules from the panel
0
d
SM
Relation between the
welding sequence
and the start signal
0: Halts the welding sequence, if the
start signal circuit is opened before
HOLD.
1: Continues the welding sequence to
completion, even if the start signal
circuit is opened after WELD1
starts.
2: Continues the welding sequence to
completion once the sequence has
started, even if the start signal
circuit is opened.
3: Performs the welding sequence in
2-stage start mode. (See 11. (2)
.)
0
e
SDT
Sets the start
stabilizing time at start
signal
01: Sets the stabilizing time to 1 ms.
05: Sets the stabilizing time to 5 ms.
10: Sets the stabilizing time to 10 ms.
20: Sets the stabilizing time to 20 ms.
05
#2 Screen
(WS and CMI are not indicated if
single-cycle or half-cycle welding
is selected.)
Display
Function
Setting
Initial
Setting
a
SU
Sets the Stepper-up
function
0: Stepper-up function OFF
1: Stepper-up operation ON
0
b
RW
Sets re-welding at the
low welding current
or the no-current
0: No re-welding carried out.
1: Performs re-welding.
0
c
WS
Determines how the
MEA-100B
functions
when the WELD
SKIP signal is input
(*)
0: Skips to the next sequence. (Skips
to COOL (CO) if WELD1 (W1) is
underway.)
1: Skips to HOLD (HLD).
0
d
HET
Sets the End signal
output time
00:
[When the Start signal is input]
Until the START input circuit is
opened, with a minimum of 10
ms.
[When the Start signal is not input]
10 ms
01: 10 ms
20: 200 ms
00
♯2
SU RW WS HET CMI
0
0
0
00 DEF
a
b
c
d