8. Stepper-Up Function
8-4
(4) Checking the Stepper-Up Status
Use this screen to check the currently operating stepper number and the weld
count for each weld force number (solenoid). (This is not a total count from stepper
1.)
Press the [MENU] key to go to the Stepper-Up Status Display Screen.
Display
a SOL1 stepper number
b Weld count for the SOL1 stepper number shown at "a"
c SOL2 stepper number
d Weld count for the SOL2 stepper number shown at "c"
(5) Resetting the Stepper Count
Resetting the stepper counter returns the stepper number to "1" and the stepper
counter to "0000" regardless of the current weld count.
(Both the weld force number 1 (SOL1) and 2 (SOL2) are reset.)
On the stepper-up status display screen, press the [RESET] key to go to the
reset screen.
On the reset screen, press the [RESET] key to reset the stepper number and the
weld count.
To cancel the reset, press any key other than the [RESET] key. The display
reverts to the stepper-up status display screen.
If the reset is done properly, the completion message is displayed for 2 seconds
before switching to the stepper-up status display screen.
SOL1 STEP:1
0000
SOL2 STEP:2
0000
c
d
a
b
RESET STEP-COUNTERS?
YES(RESET) NO(OTHER)
STEP RESET COMPLETED