12. Troubleshooting
12-1
12. Troubleshooting
If a fault occurs, the LCD panel displays a message and the trouble or caution signal is
output.
To clear the outputs, rectify the cause of fault and then input the trouble reset signal
(close [ERR RESET]) or press the [RESET] key on the front panel.
Trouble/Caution Screen
Message
a
In the case of "trouble" faults,
NO GOOD
is displayed.
In the event of "caution" faults,
CAUTION
is displayed.
b The fault code is displayed. (E01–E15)
c The "trouble" or "caution" name is displayed.
Welding does not start when trouble signal is output, even if the start signal is input.
The next welding starts when the caution signal is output, if the start signal is input.
E01
Message
CONTROLLER FAULT [C]
Time of
detection
Any time during operation
Cause of fault
The letter in [ ] at the end of the message indicates the cause of fault.
"C" is displayed when the
MEA-100B
fails to monitor the frequency
of the welding power supply.
A letter other than "C" is displayed when the CPU malfunctions.
Measures
Input the error reset signal.
If the fault occurs repeatedly, the welding power supply may be
unstable or the
MEA-100B
has some problem. Contact us or your
distributor for inspection of the welding power supply and repairs.
Output signal
Outputs the trouble [NG] signal when the fault occurs.
E02
Message
START PARITY
Time of
detection
When the start signal is accepted.
Cause of fault
The number of schedule signals (including the parity signals) is even.
Measures
Set the schedule signals and the parity signals for odd parity check.
(See 7. (4).)
Output signal
Outputs the trouble [NG] signal or the caution [CAUTION] signal
when the error arises.
NO GOOD!!
[E02]
START PARITY
c
a
b