11. Timing Chart
11-6
End Signal Output Time (HET) is set to 20
Output for 200 ms whether or not the start signal circuit is open.
(4) Re-Weld Timing Chart
When RW is set to 1 (re-weld) on the #2 screen of the SET2 screen, the re-weld is
performed when [E04: NO CURRENT] or [E05: LOW CURRENT] is detected. (See
12. Troubleshooting
.)
The time to start re-weld is 10 cycles (fixed).
・
The current for the re-weld is 5% higher than the set current.
・
During the re-weld, only the lower limit judgment is performed.
CO
W2
HLD
OFF
OFF
OFF
OFF
OFF
CO
W2
OFF
OFF
OFF
OFF
OFF
200ms
200ms
HLD
End signal(output)
[END]
Normal signal(output)
[GOOD]
Welding current
Start signal(input)
[START(1ST)]
Weld force signal(output)
[SOL1/SOL2]
Weld end signal(output)
[STP/WELD END]
OFF
OFF
OFF
SQ
CO
W2
W1
HLD
CO
W2
W1
10cyc
Fixed
OFF
OFF
Re-weld
On detection
of trouble
On detection
of caution
Caution output
[CAUTION]
End signal(output)
[END]
Normal signal(output)
[GOOD]
Trouble output
[NG]
Welding current
Start signal(input)
[START(1ST)]
Weld force signal(output)
[SOL1/SOL2]
Weld end signal(output)
[STP/WELD END]