MEA-100B
10. Interface
10-3
(2) Explanation on the External I/O Terminals
Terminal No.
Description
1
[24V-2 EXT]
If the
MEA-100B
is connected to a contact or NPN open collector
output-type device (when using the built-in power supply), connect
this terminal to terminal 2.
If the
MEA-100B
is connected to a NPN open collector output (when
using an external power supply) or PNP current output-type device,
connect this terminal to a 24 V DC external power supply.
2
[24V]
The output terminal for 24 V DC power generated in the
MEA-100B
.
Before shipment, this terminal is connected with a jumper wire to
terminal 1.
This power supply is for external input signals only. Do not use for any
other purpose.
3
[SOL COM]
*
Photo-MOS relay output: Common terminal of power supply for
solenoid. Outputs 24 V DC power.
Relay output:
Common terminal of contact output for solenoid
4
[SOL1] *
Output terminal for Weld Force 1.
Photo-MOS relay output: 24 V DC, 0.1 A
Relay output:
24 V DC, or 250 V AC or less, 0.5 A
5
[SOL2] *
Output terminal for Weld Force 2.
Photo-MOS relay output: 24 V DC, 0.1A
Relay output:
24 V DC, or 250 V AC or less, 0.5 A
6
[EXT GND]
Terminal for EXT GND.
Connect this terminal to the shielded wire of the RS-485 signal cable.
7 [RS485+]
8 [RS485-]
Terminals for RS485+ and RS485-.
Connect this terminal to the RS-485 signal cable.
9
[COM] *
Common terminals when using the Photo-MOS relay output with the
external power supply.
10
[CAUTION]
*
Output terminal for [CAUTION] signal.
When a "caution" fault occurs, this circuit is closed.
(Preset the fault signal attribute so that the caution signal can be output
when the fault occurs. For details, see 9. (2)
.)
The circuit is opened when [ERR RESET] is closed.
Photo-MOS relay output: 24 V DC, 0.1 A
11
[STP/WELD
END] *
Output terminal for Step End [STP END] and Weld End [WELD END]
signals
The Stepper-up function is ON (SU:1)
Stepper-up end signal is output
The circuit is closed upon completion of the stepper-up operation.
The Stepper-up function is OFF (SU:0)
Welding end signal is output
The circuit is closed upon completion of welding within a welding
sequence.
Note: For timing details, see
11. Timing Chart
.
Photo-MOS relay output: 24 V DC, 0.1 A
12
[READY] *
Output terminal for [READY] signal.
The circuit is closed when the
MEA-100B
is ready for welding.
The READY signal is turned off until transmission of the confirmation
data is completed after data is received in the bi-directional
communication. (See 14. (7).)
Photo-MOS relay output: 24 V DC, 0.1 A
* See (B) and (C) in
13. (3) Model No.-Spec Reference Table
.