MEA-100B
8. Stepper-Up Function
8-3
(3) Stepper-Up (-Down) Rate Setting
ATTENTION
Set the value of “the welding current x the stepper-up rate” so that it does not
exceed the following value:
The set maximum current (6. (3)) in the secondary constant-current control
99.9% in the power supply voltage fluctuation compensation control
When the value over the maximum current is set, the fault code [E09: STEPUP
RATE TROUBLE] is given at the input of the start signal. (For faults, see 12.)
Press the [MENU] key to go to the Stepper-Up Rate Setting Screen.
Move the cursor to "e" and select the welding head from SOL1 and SOL2.
Move the cursor to "a"–"d" and set the stepper-up rates for steppers 2–5.
Set the rate in a percentage to the set value of the welding current expressed as
100% (See 7. (2)). Setting range is 50% to 150%.
a: Up rate for Stepper 2
b: Up rate for Stepper 3
c: Up rate for Stepper 4
d: Up rate for Stepper 5
<Setting Example>
Welding current: 0.40 kA
Stepper No. Stepper-Up (-Down) Rate Stepper Count
1
-
1500
2
105%
1500
3
110%
3000
4
95%
1500
5
90%
2500
STEP UP CURR.% 2:100
3:100 4:100 5:100
1
b
c
d
e
a
105%
110%
95%
90%
Stepper-up
completed
1500
1500
1500
3000
2500
Stepper
Count
Stepper No.
1
2
3
4
5
Set current
0.40kA
Current
[kA]
00
1500
3000
6000
7500
10000
Weld count
[times]
0.42kA
0.44kA
0.38kA
0.36kA
Содержание MEA-100B