9. Detail Settings (SET2 Screen)
9-3
Display
Function
Setting
Initial
Setting
e
CMI
Sets the Current
monitor cycle
(Ignores downslopes
regardless of the
setting)
DEF: Ignores errors in the first 1.0
cycle and upslopes.
00.0: Detects errors from the start in
all cycles.
00.5: Ignores errors in the first half-
cycle.
01.0: Ignores errors in the first full
cycle.
↓
(The setting can be changed
every half-cycle.)
10.0: Ignores errors in the first 10.0
cycles.
DEF
(*) Skips to the next sequence at the time of the WELD SKIP signal is turned from on
to off in the sequence. If the WELD SKIP signal is turned off, it does not skip to the
next sequence.
#3 Screen
This screen indicates different data according to the welding and control
methods selected.
<Screen for Multi-Cycle Welding>
<Screen for Single-Cycle Welding>
<Screen for Half-Cycle Welding>
♯3
NCL: W1 03%
NCI
W2 03% 01.0
a
b
f
♯3
NCL:1ST
00%
2ND
00%
c
d
♯3
NCL:HALF 00%
e