Installation
35
0000010064-007- GB
Installation
6.3.7
Electrical connection
The controls of an extraction system require a floating contact. An auxiliary
contactor can be controlled using a 2-wire control line leading out. The maxi
-
mum control voltage / current is 240VAC / Imax=1A.
WARNING!
Dangerous electric voltage!
All work on the electrical equipment, including connection to the mains supply,
may only be performed by a qualified electrician.
Disconnect the machine from the mains supply before working on the electrical
equipment.
•
A round plug device under the sliding table is used to establish the connec
-
tion. Use a rubber hose line (H07RN-F), cross section 5x 2.5 mm2 as the
supply line.
•
After connecting the supply line, check the rotational direction of the main
saw motor by briefly starting up and, if necessary, correct it.
•
Pay attention to the rotational direction arrow on the saw blade cover!
•
The owner/user must provide a short-circuit protection!
•
Do not route supply lines or the potential-free contact through the support
arm.
Содержание WA 6
Страница 2: ...2 0000010064 007 GB Altendorf RAPIDO are registered trademarks of Altendorf GmbH in various countries...
Страница 7: ...Machine identification 7 0000010064 007 GB Machine identification...
Страница 11: ...Identification 11 0000010064 007 GB Identification EC prototype testing certificate...
Страница 12: ...Identification 12 Identification 0000010064 007 GB DGUV Test Certificate...
Страница 13: ...Identification 13 0000010064 007 GB Identification Certificate renewal...
Страница 14: ...Identification 14 Identification 0000010064 007 GB C US certificate...
Страница 75: ...Maintenance and repairs 75 0000010064 007 GB Maintenance and repairs...
Страница 76: ...Maintenance and repairs 76 Maintenance and repairs 0000010064 007 GB...