Function
code
Function
Name
LCD
Display
Range of settings
Default
Change
MODBUS
Address
P5.16
Step T6
Program
Operating
Setting
Program
Operating
Setting 6
1F
○
0610
P5.17
Step T7
Program
Operating
Setting
Program
Operating
Setting 7
1 F/r~4 F/r
1F
○
0611
P5.18
PLC record
clear
PLC
record
clear
0: Disable 1: Enable
(After zero-clearing
this function code
reset to 0)
0
× 0612
P5.19
Record of
PLC steps
Record of
PLC steps
0~7 0
* 0613
P5.20
PLC
operating
Time
PLC
operating
Time
0.0~3600 0.0
* 0614
P6: Wobble Frequency Operating
Function
code
Function
Name
LCD
Display
Range of settings
Default
Change
MODBUS
Address
P6.00
Wobble
frequency
operation
restart
mode
Wobble
frequency
restart
0: Restart at the
freq. and
direction before
stop
1: Restart
0
× 0700
P6.01
Save
wobble
frequency
running
parameters
when
power loss
Save
wobble
frequency
running
parameters
0: not save
1: save
0
× 0701
P6.02
Preset of
wobble
frequency
Preset of
wobble
frequency
3004GB or below:
0.00~650.0Hz
35R5GB/37R5PB
or above:
0.00~400.0Hz
0.00Hz
○