![Alpha ALPHA6000 Series Скачать руководство пользователя страница 175](http://html1.mh-extra.com/html/alpha/alpha6000-series/alpha6000-series_manual_2905270175.webp)
Chapter 5 Parameter Introductions
http://www.acdrive-china.com
175
0: No display
1: Display
Note:
◆
If PC.03 is set to 1, output current will be displayed with unit “A” in monitoring state,
and the unit indicator “A” will lit up. If it is set to 0, output current will not be
displayed.
PC.04 Reference frequency (Hz, flashes)
Range: 0,1
【
1
】
0: No display
1: Display
Note:
◆
PC.04 can be set to 1 and press shift key >> can switch to reference frequency
monitoring in monitoring state. When switch to reference frequency monitoring, the
“Hz” unit indicator will flicker. If P0.01 is set to 1, which means the reference
frequency can be changed by keyboard digital encoder, turning left/right the digital
encoder will change the reference frequency. If keep on turning , the length of every
step can rise from 0.01 Hz to 0.1 Hz and the max 1 Hz. With this function, the
regulation can be quick. For details, please refer to P0.11 (step length of digital
encoder regulation).
PC.05 Rotate speed (r/min)
Range: 0,1
【
0
】
PC.06 Reference speed (r/min flashes)
Range: 0,1
【
0
】
0: No display
1: Display
Note:
◆
If PC.05 is set to 1, rotate speed will be displayed in monitoring state, and the unit
indicator “r/min” (combination of unit “Hz” and” A”) will be lit up. If it is set to 0,
rotate speed will not be displayed.
◆
If PC.06 is set to 1, reference speed will be displayed in monitoring state, and the unit
indicator “r/min” (combination of unit “Hz” and “A”) will be lit up and flickered.
◆
If PC.06 is set to 1, when the user press shift key >> to switch to monitor this
parameter or Rotate speed:
In simple run mode: if P0.01 is set to 1, Reference speed can be adjusted online and
saved the reference frequency value into parameter P0.00 by pressing “ENTER” key.
In PID run mode: If P7.00 is set to 0 and P7.01 is set to 9 (PG or Single-phase speed
measuring input), PID reference (reference speed) can be adjusted online and saved
into parameter P7.03 by pressing “ENTER” key. If P7.01 is not set to 9, it cannot be
adjusted online.
PC.07 Linear speed (m/s)
Range: 0,1
【
0
】
PC.08 Reference linear speed (m/s flashes)
Range: 0,1
【
0
】
0: No display
1: Display
Note:
◆
If PC.07 is set to 1, line speed will be displayed in monitoring state, and the unit