![Alpha ALPHA6000 Series Скачать руководство пользователя страница 114](http://html1.mh-extra.com/html/alpha/alpha6000-series/alpha6000-series_manual_2905270114.webp)
Chapter 5 Parameter Introductions
http://www.acdrive-china.com
114
0.01Hz/(6/(5*PA.00))r/min; When it is reference speed, the unit is
(6/(5*PA.00))r/min under common operation mode and 1r/min under the digital PID
control mode.
Example:
In the range, when P0.11 is set to 100, turn left/right the digital encoder one cycle, the
reference frequency will decrease/increase 30.00Hz and the rotate speed will
decrease/increase 900 turns every minute; when P0.11 is set to 10, the reference
frequency will decrease/increase 3.00Hz and the rotate speed will decrease/increase
900 turns every minute
P0.12 V/F curves setting
Range: 0
~
4
【
0
】
P0.13 V/F frequency value F1
Range: 0.0
~
P0.15
【
10.00Hz
】
P0.14 V/F voltage value V1
Range: 0
~
100.0%
【
20.0%
】
P0.15 V/F frequency value F2
Range: P0.13
~
P0.17
【
25.00Hz
】
P0.16 V/F voltage value V2
Range: 0
~
100.0%
【
50.0%
】
P0.17 V/F frequency value F3
Range: P0.15
~
P0.06
【
40.00Hz
】
P0.18 V/F voltage value V3
Range: 0
~
100.0%
【
80.0%
】
Note:
The above listed parameters can define flexible V/F setting mode to meet the special
load characteristics demand.
Ooutput Voltagey(V)
Output Frequency(Hz)
Max output
Voltage (P0.10)
Basic Frequency (P0.06)
0
3
2
1
Fig. 5-0-2 Torque-reducing curve
Содержание ALPHA6000 Series
Страница 7: ...Chapter 2 Installation and Wiring http www acdrive china com 7...
Страница 38: ...Chapter 2 Installation and Wiring http www acdrive china com 38 Fig 2 33 3R75GB 3004GB Wiring diagram...
Страница 239: ...Appendix 4 MODBUS Communication http www acdrive china com 239 25H for the user debugging...