Chapter 4 Parameter Index
http://www.acdrive-china.com
86
Function
code
Function
Name
LCD
Display
Range of settings
Default
Change
MODBUS
Address
P4.16
PG Pulse
Range
PG Pulse
Range
1~9999 1024
○
0510
P4.17
AO1
function
definitio
n
AO1termin
al output
r
× 0511
P4.18
AO2
function
definitio
n
AO2termin
al output
1
× 0512
P4.19
DO
output
DO output
0: Output frequency
before
compensation
(0~Max
Frequency)
1: Output current
(0~2* ac drive
rated current)
2: Output voltage
(0~Max Voltage)
3: PID feed
(0~10V)
4: PID feedback
(0~10V)
5: Adjust signals
(5V)
6: Output torque
(0~2*ac drive
rated torque)
7: Output power
(0~2*Ac drive
rated power)
8: Bus voltage
(0~1000V)
9: AI1 (0~10V)
10: AI2
(0~10V/0~20mA
)
11: Output
frequency after
compensation
(0~maximum
frequency)
12~14: Reserved
15: NULL
11
× 0513