![Alpha ALPHA6000 Series Скачать руководство пользователя страница 102](http://html1.mh-extra.com/html/alpha/alpha6000-series/alpha6000-series_manual_2905270102.webp)
Chapter 4 Parameter Index
http://www.acdrive-china.com
102
Function
code
Function
Name
LCD
Display
Range of
settings
Default
Change
MODBUS
Address
Pd.02
Pre-overload
detection
Level
Pre-overloa
d detection
Level
20.0
~
200.0%
160.0%
× 0E02
Pd.03
Pre-Overloa
d detection
time
Pre-Overlo
ad
detection
time
0.0
~
60.0s
60.0s
× 0E03
Pd.04
Current
amplitude
limit
Current
amplitude
limit
0:Invalid
1: Valid during
Acceleration
and
deceleration,
invalid in
constant
speed
Operation
2: Valid
1
○
0E04
Pd.05
Current
amplitude
limiting
level
Current
amplitude
limiting
level
Type G:80
~
180%
Type P:60
~
140%
G:150%
P:120%
○
0E05
Pd.06
Over-voltag
e at stall
function
selection
Over-volta
ge at stall
function
selection
0:Disabled (The
proposed
option, when
braking
resistor is
mounted)
1:Enabled
1
× 0E06
Pd.07
Over-voltag
e point at
stall
Over-volta
ge point at
stall
3004GB or
below:
110.0
~
150.0% (Bus
voltage)
35R5GB/37R5P
B or above:
120.0
~
150.0% (Bus
voltage)
220V:
120.0%
380V:
140.0%
× 0E07