P6.02 is used to define the operating frequency before entering wobble frequency
operation mode.
◆
P6.03 is used to define the time when the ac drive operates at wobble-preset
frequency.
◆
P6.04 is used to define the range of wobble operating frequency. The actual value is
P0.00×P6.04.
◆
P6.07 is used to define a cycle of wobble frequency operation including rising and
falling processes.
◆
P6.08 is used to define wobble ratio, which is the ratio of UP time to DOWN time.
P6.09 Random wobble selection
Range: 0,1
【
0
】
P6.10 MAX ratio of random wobble
Range: 0.1
~
10
【
10
】
P6.11 MIN ratio of random wobble
Range: 0.1
~
10
【
0.1
】
Note:
◆
P6.09 is used to select a fixed wobble ratio value defined by P6.08 or a random value
between P6.11~P6.10.
Wobble frequency operation has two starting modes:
◆
Auto mode: If the setting of P0.01 is 10, the ac drive will enter wobble frequency
operation mode automatically when power is on.
◆
Manual mode: When the setting of P0.01 is not 10, the ac drive first operates at other
defined mode. Then if the multi-function terminal (Xi is set to 45) is valid, the ac drive
will enter wobble frequency operation mode.
Distinction:
Compared with the auto mode, the manual mode omits the operating at
preset frequency.
Wobble frequency operation process: First, the ac drive speeds up to the preset of
wobble frequency (P6.02) within the Acc time and then waits for a certain time (P6.03).
The ac drive transits to the central frequency within Acc/Dec time, and at last the ac
drive operates according to the preset wobble frequency amplitude (P6.04), skip
frequency (P6.05), skip time (P6.06), wobble frequency operating cycle (P6.07) and
wobble ratio (P6.08) until it receives a stop command and stops within Dec time.
If the frequency setting selected the combination of frequency setting 1 and frequency
setting 2, the central frequency will be the sum of P0.00 and frequency setting 2. If not,
the central frequency would be the value of P0.00. The wobble frequency operation is
shown in Fig.5-6-1.