P3.17 Preset operating time
(
3004GB
and below models
)
Range: 0.0
~
3.0s
【
1s
】
Note:
For model 3004GB and belows: function code P3.17 is valid for fixed-length
arriving hold time setting. For models above ,P3.17 is the Output function of
Relay 2.See description of P3.16 above;
When P3.13=28 or P3.16 =28, the DO or Relay1 output is selected as
"fixed-length arriving”, the setting of P3.17 will be effective.
When the P3.17 is set as 0: fixed-length arriving output terminal will hold the
output level until the length is reset.
When the P3.17 is set not as 0: the value of P3.17 will be the time during which the
fixed-length arriving output terminal will keep the output level .
P3.18 FAR detection width
Range: 0.00
~
10.00Hz
【
2.50Hz
】
Note:
◆
This function used to adjust FAR detection bandwidth, when the output frequency
reaches to the reference frequency. The adjusted range is from 0 to ±10.00 Hz of
reference frequency. If the ac drive’s output frequency is within the detection width of
reference frequency, a pulse signal will be output, as shown in Fig. 5-3-8.
Detection width
Time
Time
Reference
Freq.
Operating Freq.(Hz)
FAR signal
Fig. 5-3-8 FAR detection diagram
P3.19 Frequency detection
threshold (FDT)level
Range:
3004GB and the below models: 0.00
~
650.0Hz
【
50.00Hz
】
35R5GB/37R5PB and the above models:
0.00
~
400.0Hz
【
50.00Hz
】