background image

18 

#  NAME 

DESCRIPTION 

7  CLOSE 

Momentary or continuous signal. On/
Off mode set by Switch #1

 

 

WITH SWITCH 1 OFF:

 Once activated the gate will 

close fully.  Activation while the gate is opening has no 
effect. Continuous signal required to move the gate 
when in the alarm mode.  

WITH SWITCH 1 ON:

 Gate does not respond to 

pushbutton input when in the normal mode. Continuous 
signal required to move the gate when in the alarm 
mode.   

8  STOP 

Momentary or continuous signal.   

 

Overrides all other signals.  Once activated, the gate will 
immediately stop and await a new command.  If the 
STOP input is continuously activated, the gate will not 
move.  

9  SHADOW LOOP  Momentary or continuous signal.  

 

This input is active only when the gate is at rest in the 
fully OPEN or CLOSED position, it has no effect on the 
gate when closing or opening.  Continuous activation will 
prevent the gate from moving in the open or close 
direction (depending on gate position).  When the input 
is removed normal operation is resumed.  This input is 
intended for a vehicle loop detector to sense a vehicle in 
the gate path.  Connect here and to terminal #16 
COMMON.  Multiple devices may be connected in 
parallel.  

10  CLOSE PHOTO 

Momentary or continuous signal.  

 

This input is active only when referenced to the closing 
direction, it has no effect on the gate when opening or 
about to open.  If activated when the gate is closing the 
gate will stop, pause and reverse in the open direction 
for 1/2 second (approx. 2 inches) and stop.  Continuous 
activation will prevent the gate from moving in the close 
direction.  When the input is removed normal operation 
is resumed.  If the Timer-To-Close function initiated the 
close movement and Switch S2 (Re-close)  is ON, the 
gate will automatically re-close from a partially closed 
position after the input to Close Photo is removed. 
Continuous activation while the gate is open will prevent 
the Timer-To-Close function (if enabled) from 
automatically closing the gate.   This input is intended for 
photoelectric eye systems and other non-contact devices 
as appropriate.  Connect here and to terminal #16 
COMMON.  Multiple devices may be connected in 
parallel.  

11  REV LOOP 

Momentary or continuous signal.  

 

This input is active only when the gate is closing or when 
it’s fully open and the Close Timer is operative.  All 
stand-alone vehicle detectors, photo-eyes and active 
edges should be connected here and to terminals #3 or 
#13 COMMON.  Multiple devices may be connected in 
parallel.  

#  NAME 

DESCRIPTION 

12  OPEN EDGE 

Momentary or continuous signal.   

 

This input is active only when referenced to the opening 
direction, it has no effect on the gate when closing or about to 
close.  If activated when the gate is opening the gate will 
stop, pause and reverse in the close direction for 1/2 second 
(approx. 2 inches) and stop. Continuous activation will 
prevent the gate from moving in the open direction.  If a 
second activation occurs before the limit switch is activated 
the gate will stop and a require a renewed, intended input to 
move in the open direction and before an automatic 
activation device (timer, etc.) will operate. This input is 
intended for Electric Gate Edge systems and other minimum-
contact devices as appropriate.  Connect here and to 
terminal #16 COMMON.  Multiple devices may be connected 
in parallel.  

13  CLOSE EDGE 

Momentary or continuous signal.  

 

This input is active only when referenced to the closing 
direction, it has no effect on the gate when opening or about 
to open.  If activated when the gate is closing the gate will 
stop, pause and reverse in the open direction for 1/2 second 
(approx. 2 inches) and stop.  Continuous activation will 
prevent the gate from moving in the close direction. 
Continuous activation while the gate is open will prevent the 
Timer-To-Close function (if enabled) from automatically 
closing the gate.  If a second activation occurs before the 
limit switch is activated the gate will stop and a require a 
renewed, intended input to move in the close direction and 
before an automatic activation device (timer, etc.) will 
operate. This input is intended for Electric Gate Edge 
systems and other minimum-contact devices as appropriate.  
Connect here and to terminal #16 COMMON.  Multiple 
devices may be connected in parallel.  

14  MASTER OPEN 

Momentary or continuous signal.  Master 
(output configuration)  
 

 

This terminal is used to coordinate two independent systems 
(two control box/mechanical unit combinations controlling 
separate gate leaves).  Connects to terminal #6 (OPEN) in 
the companion control box and controls the direction of 
movement in the companion box (Switch S3 ON).  

 

15  MASTER CLOSE  Momentary or continuous signal.  Master 

(output configuration)  
 

 

16  COMMON 

Common connection for low voltage 
signal inputs, terminals 3 through 15. 

17  CLOSE LIMIT 

SWITCH 

Connection for Limit Switch Input — See 
page 13, Fig. 13 or page 14, Fig. 15, for 
Limit Switch Wiring (single or bi-parting) 

This terminal is used to coordinate two independent systems 
(two control box/mechanical unit combinations controlling 
separate gate leaves).  Connects to terminal #7 (CLOSE) in 
the companion control box and controls the direction of 
movement in the companion box (Switch S3 ON).  

 

 TERMINAL STRIP REFERENCE CHART 

C: 

INSTALLING THE OPERATOR 

Содержание ANSI/UL 325

Страница 1: ...for Vehicular gate operators GATE STAR 4000 Model GS4000 Heavy Duty Commercial Vehicular Swing Gate Operator READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE SAVE THESE INSTRUCTIONS 104950 Seria...

Страница 2: ...ere to protect you and your equipment Pay close attention to these boxes as you follow the manual WARNING Indicates a MECHANICAL hazard of INJURY OR DEATH Gives instructions to avoid the hazard CAUTIO...

Страница 3: ...cal parts Whether the overload is activated before the Torque Limiter slips will depend upon the tightness of the adjustment of the Torque Limiter This adjustment will be explained in the final check...

Страница 4: ...re a handhold or toehold may be achieved injuries may occur when people put arms through the openings or children ride the gate by standing on the bars and holding on to the gate THIS POTENTIAL HAZARD...

Страница 5: ...the GS4000 Control Box cover is removed high voltage will be exposed EVEN IF THE RED POWER LIGHT IS NOT LIGHTED HIGH VOLTAGE AC MAY STILL BE PRESENT ON TERMINALS L1 AND L2 NEVER LEAVE THE INSTALLATIO...

Страница 6: ...r attention to the bolt pattern and the location of the mounting holes with respect to the center line of the gate post It is critical for the proper operation of the Arm that the center line of the s...

Страница 7: ...O K DO NOT USE ANY PVC INSULATED WIRE PVC insulation will absorb moisture that may affect Detector operation WIRE SIZE SHOULD BE 16 GA STRANDED OR LARGER VEHICLE DETECTOR LOOP BLANKING FOR SWING GATES...

Страница 8: ...lt Amperes Watts IF TWO MECHANICAL UNITS ARE TO BE USED FOR A BI PARTING GATE SYSTEM THEN A 1000 VOLT AMPERE WATT TRANSFORMER MUST BE USED Operating from a three 3 phase line will require the use of a...

Страница 9: ...or connecting accessory equipment to the control box terminal strip and for limit switch control wires 7 Four 1 2 diameter concrete redhead bolts with hex nuts flat washers and lock washers For attach...

Страница 10: ...n accordance with the drawing of Figure 6 INSTALLING THE GS4000 ARM Temporarily locate the Gate Bracket on the Gate with C clamps or by tack welding Install the gate bracket to the gate so the gate ar...

Страница 11: ...t entry Run a flexible water tight conduit from the service junction box to the GS4000 CONTROL BOX Pull three 14 wires from the service junction box in this conduit to the GS4000 Control Box If the GS...

Страница 12: ...eriod of time is long enough to damage solid state components and many times other components The key to success is a very low resistance path from the surge protector to ground for these currents in...

Страница 13: ...tion one operator must be a Left Hand unit and the other a Right Hand unit The two motors of the Bi Parting GS4000 s will be wired in parallel BOTH motors will run until both are shut off If the two g...

Страница 14: ...14 C INSTALLING THE OPERATOR Figure 15 Bi Parting Installation Limit Motor Wiring Diagram 110092...

Страница 15: ...sary as the GS4000 control board 24 VAC output is not referenced to ground See Figure 16 and the following text for proper connection FOUR WIRE RECEIVERS Four wire receivers replace the spade terminal...

Страница 16: ...from a location where it will be switched off at the GS4000 Power Switch CONNECTING THE VEHICLE DETECTOR For a REVERSING LOOP connection of the Vehicle Detector the relay or presence output of the Det...

Страница 17: ...ME DESCRIPTION 1 24 VAC Provides maximum 10 VA auxiliary power for accessories 2 24 VAC Provides maximum 10 VA auxiliary power for accessories 3 ALTERNATE Momentary input must be released and re enter...

Страница 18: ...continuous signal This input is active only when referenced to the opening direction it has no effect on the gate when closing or about to close If activated when the gate is opening the gate will st...

Страница 19: ...operation as described in the text that follows OPEN CLOSE PUSH BUTTON ENABLE DISABLE PATENT NO 6 611 205 Switch S1 controls the Push Button Enable Disable Feature SWITCH 1 OFF Activating the Open or...

Страница 20: ...the application of power 1 Check that the GS4000 power switch is off 2 Check that the breaker at the power panel is on 3 With a voltmeter on the proper scale check that the line voltage at terminals...

Страница 21: ...tact Sensor light comes on remains on until the connection is removed Observe that the both Motor Open and Motor Close lights are momentarily ON then the Motor Open light goes out and the Motor Close...

Страница 22: ...ment run the GS4000 open and closed several times to ensure that the positions set will be retained SMART SETTING MAXIMUM RUN TIMER The GS4000 is equipped with a Self adjusting MAximum Run Timer SMART...

Страница 23: ...LM IN BOTH DIRECTIONS OF TRAVEL REPEAT THIS TEST UNTIL YOU ARE SATISFIED YOU HAVE THE MOST SENSITIVE SETTING OF THE POTENTIOMETERS Disconnect the crank arm from the output shaft to permit re installat...

Страница 24: ...signs shipped with your GS4000 Operator See Figure 4 Page 5 of this manual must be installed in prominent positions on both sides of your gate Keep them clean and legible Read and put into practice th...

Страница 25: ...ontact sensors After adjusting the force or limits of travel retest the gate operator Failure to adjust and retest the gate operator properly can increase the risk of injury or death KNOW YOUR GATE AR...

Страница 26: ...26 1 2 3 4 5 7 6 8 9 10 11 12 13 14 15 16 17 18 19 20 106359 Figure 27 GS4000 Mechanical Unit Exploded View MECHANICAL UNIT EXPLODED VIEW...

Страница 27: ...HANDY BOX 1 7 8 DEEP 19 102735 HANDY BOX COVER WITH LABEL SCREWS 20 010231 CLUTCH DISC ITEM PART DESCRIPTION 1 109966 CONTROL BOX W COVER 2 110074 CONTROL BOARD 3 100997 CIRCUIT BREAKER 4 010412 ON O...

Страница 28: ...labor charges for dismantling or reinstalling a repaired or replaced unit or replacement batteries These warranties are in lieu of all other warranties either expressed or implied All implied warranti...

Отзывы: