Allstar ANSI/UL 325 Скачать руководство пользователя страница 3

The Allstar Gate Star 4000 (GS4000) Vehicular Gate Operator will 
provide convenience and assurance to the ultimate users for many 
years.  It is ruggedly built of the finest materials and has been 
thoroughly inspected and tested at the Allstar factory.  It has many 
features that will aid in the installation and testing of the complete gate 
system.  The GS4000  is certified to comply with UL Standard for 
Safety 325, as  revised March 1, 2000.  (115 Volt version only.) 
 

 

The GS4000 Vehicular Swing Gate Operator is designated a Class I 
Residential Vehicular Swing Gate Operator, and is intended to operate 
a vehicular swing  gate installed on a residential home, maximum of 
four single families in the dwelling, or a garage or parking area 
associated with that home.  The GS4000 vehicular gate operator is also 
designated Class II (Commercial location or multi-family home); III 
(industrial location not intended to service the general public); and IV 
(secure or restricted access locations, ie. airports and prisons).  The 
GS4000 may be used in any Class location. 
Because the Allstar GS4000 (as well as gate operators sold by other 
manufactures) is designed to start and move gates weighing as much as 
1000 pounds,---the Allstar GS4000 is capable of producing high levels 
of force.  It is important in the design of the total gate system that 
designers, installers and users be aware of the hazards that may be 
associated with the 

IMPROPER

 design, installation and use of 

Vehicular Gate systems and Gate Operators. 

 

The gate operator is only one part of a complete automatic gate 
operating system.  As each location and usage is different, a properly 
designed system will include all applicable safety devices. 

 
The GS4000 CGA2K™ Technology provides several features that 
can help reduce the hazards of your gate system. 

 

Built-In Overload Detector Sensing System 

The Allstar GS4000 has a built-in "overload detector" that can help 
reduce the hazards of your gate system.  This device, however, must not 
be considered as the primary defense system.  Consider all available 
options (electric leading edges, photoelectric sensors, protective screen 
mesh, etc) to eliminate hazards in your gate system design. 

 

The Allstar GS4000 built-in overload detector will activate if there is an 
abrupt increase in motor current above that normally required to move 
the gate.  The overload detection point is an adjustable setting that must 
be determined at the time of installation.  This setting must be tested 
periodically to ensure proper operation. Diligent maintenance of the 
gate hinges and hardware will assure the most responsive operation of 
the overload detector.  See pages 17 & 23. 
 
ADVISE THE PURCHASER TO CHECK THE SENSITIVITY OF 
THE OVERLOAD PERIODICALLY AND, AFTER REMOVING 
THE CONTROL BOX COVER, LOG THE DATE TESTED ON THE 
LOG  LOCATED ON PAGE TWO OF THIS MANUAL (See Figure 1, 
pg. 2.) 
 
 
 

The GS4000 is also provided with a Torque Limiter that may be 
adjusted to "slip" when an obstruction is encountered.  However, the 
purpose of the Torque Limiter is to protect the GS4000 mechanical 
parts.  Whether the overload is activated before the Torque Limiter slips 
will depend upon the "tightness" of the adjustment of the Torque 
Limiter.  This adjustment will be explained in the final check out of the 
GS4000. 

 

Connections for External Entrapment Prevention Sensors

 

Because all gate system installations are different, the GS4000 control 
panel provides independent connections for Open and Close non-
contact (photoelectric) and contact (edge) sensors.  In this way a 
photoelectric sensor could be utilized to guard the gate area when 
closing and an edge sensor would provide the protection when opening.  
Depending on the particular application a combination contact and non-
contact sensor protection system for the open and close directions may 
provide more effective entrapment protection than a single device for 
both directions.  See pages 4, 5, 13, 18, 24, and 25. 

Audio Alarm and AlarmAble™ Open/Close Push Button Enable-
on-Alarm Only (Patent No. 6,611,205)  

The GS4000 has an audio alarm that sounds when a second occurrence 
of the built-in overload activation is registered before an end limit 
(open or close) is reached.  The alarm continues to sound warning until 
a fixed wire input is activated or five (5) minutes pass.  As with the 
built-in overload detector,  Diligent maintenance of the gate hinges and 
hardware will avoid nuisance operation of the overload detector and 
thereby avoid nuisance operation of the audio alarm.  Allstar’s patented 
AlarmAble™ Open/Close Push Button Enable-on-Alarm Only feature 
can be set to provide a secure control station that will be functional in 
an emergency  situation.  See pages 18, 19, 24, and 25. 

SMART™ Self Adjusting MAximum Run Timer

 

The GS4000 has a 

S

elf adjusting 

MA

ximum 

R

un 

T

imer, SMART™.  

The amount of time for the first few cycles of operation are registered 
and averaged within the motor controller circuitry.  After the first few 
initial cycles, if the gate is activated and no other command is given or 
an end limit (open or close) is not reached in the previously counted 
cycle time plus approximately 4 seconds, the operator will be turned 
off.  See page 22. 

 

OTHER FEATURES

 

Auto Close Timer:

  Adjustable from 2 to 60 seconds, provides an 

automatic closure of the gate from the full open position.  See page 19. 

 

Timer Re-close On/Off Switch:  

Enables an automatic closure of the 

gate from a partially closed position if the close movement  was 
initiated by the Auto Close Timer and the close cycle was interrupted 
by a non-contact (photoelectric) sensor input.  See page 20. 

 

Diagnostic LEDs on the Motor Controller Board:

  Provides a visual 

indication of the status of the gate system operation.  See page 20. 
 

NOTICE - THE IMPORTANT SAFEGUARDS AND 

INSTRUCTIONS IN THIS MANUAL  CANNOT 
COVER ALL POSSIBLE CONDITIONS AND 

SITUATIONS WHICH MAY OCCUR DURING ITS USE.  IT 
MUST BE UNDERSTOOD THAT COMMON SENSE AND 
CAUTION MUST BE EXERCISED BY THE PERSON(S) 
INSTALLING, MAINTAINING AND OPERATING THE 
EQUIPMENT DESCRIBED HEREIN.  DO NOT USE THIS 
EQUIPMENT FOR ANY OTHER THAN ITS INTENDED 
PURPOSE — OPERATING A SWING GATE. 

 

NOTICE - BEFORE ATTEMPTING INSTALLATION,  

READ THIS MANUAL CAREFULLY  SO YOU WILL 

BE THOROUGHLY FAMILIAR WITH THE 
FEATURES OF THE GS4000 AND ITS PROPER 
INSTALLATION PROCEDURES

 

PRE-INSTALLATION NOTES 

Содержание ANSI/UL 325

Страница 1: ...for Vehicular gate operators GATE STAR 4000 Model GS4000 Heavy Duty Commercial Vehicular Swing Gate Operator READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE SAVE THESE INSTRUCTIONS 104950 Seria...

Страница 2: ...ere to protect you and your equipment Pay close attention to these boxes as you follow the manual WARNING Indicates a MECHANICAL hazard of INJURY OR DEATH Gives instructions to avoid the hazard CAUTIO...

Страница 3: ...cal parts Whether the overload is activated before the Torque Limiter slips will depend upon the tightness of the adjustment of the Torque Limiter This adjustment will be explained in the final check...

Страница 4: ...re a handhold or toehold may be achieved injuries may occur when people put arms through the openings or children ride the gate by standing on the bars and holding on to the gate THIS POTENTIAL HAZARD...

Страница 5: ...the GS4000 Control Box cover is removed high voltage will be exposed EVEN IF THE RED POWER LIGHT IS NOT LIGHTED HIGH VOLTAGE AC MAY STILL BE PRESENT ON TERMINALS L1 AND L2 NEVER LEAVE THE INSTALLATIO...

Страница 6: ...r attention to the bolt pattern and the location of the mounting holes with respect to the center line of the gate post It is critical for the proper operation of the Arm that the center line of the s...

Страница 7: ...O K DO NOT USE ANY PVC INSULATED WIRE PVC insulation will absorb moisture that may affect Detector operation WIRE SIZE SHOULD BE 16 GA STRANDED OR LARGER VEHICLE DETECTOR LOOP BLANKING FOR SWING GATES...

Страница 8: ...lt Amperes Watts IF TWO MECHANICAL UNITS ARE TO BE USED FOR A BI PARTING GATE SYSTEM THEN A 1000 VOLT AMPERE WATT TRANSFORMER MUST BE USED Operating from a three 3 phase line will require the use of a...

Страница 9: ...or connecting accessory equipment to the control box terminal strip and for limit switch control wires 7 Four 1 2 diameter concrete redhead bolts with hex nuts flat washers and lock washers For attach...

Страница 10: ...n accordance with the drawing of Figure 6 INSTALLING THE GS4000 ARM Temporarily locate the Gate Bracket on the Gate with C clamps or by tack welding Install the gate bracket to the gate so the gate ar...

Страница 11: ...t entry Run a flexible water tight conduit from the service junction box to the GS4000 CONTROL BOX Pull three 14 wires from the service junction box in this conduit to the GS4000 Control Box If the GS...

Страница 12: ...eriod of time is long enough to damage solid state components and many times other components The key to success is a very low resistance path from the surge protector to ground for these currents in...

Страница 13: ...tion one operator must be a Left Hand unit and the other a Right Hand unit The two motors of the Bi Parting GS4000 s will be wired in parallel BOTH motors will run until both are shut off If the two g...

Страница 14: ...14 C INSTALLING THE OPERATOR Figure 15 Bi Parting Installation Limit Motor Wiring Diagram 110092...

Страница 15: ...sary as the GS4000 control board 24 VAC output is not referenced to ground See Figure 16 and the following text for proper connection FOUR WIRE RECEIVERS Four wire receivers replace the spade terminal...

Страница 16: ...from a location where it will be switched off at the GS4000 Power Switch CONNECTING THE VEHICLE DETECTOR For a REVERSING LOOP connection of the Vehicle Detector the relay or presence output of the Det...

Страница 17: ...ME DESCRIPTION 1 24 VAC Provides maximum 10 VA auxiliary power for accessories 2 24 VAC Provides maximum 10 VA auxiliary power for accessories 3 ALTERNATE Momentary input must be released and re enter...

Страница 18: ...continuous signal This input is active only when referenced to the opening direction it has no effect on the gate when closing or about to close If activated when the gate is opening the gate will st...

Страница 19: ...operation as described in the text that follows OPEN CLOSE PUSH BUTTON ENABLE DISABLE PATENT NO 6 611 205 Switch S1 controls the Push Button Enable Disable Feature SWITCH 1 OFF Activating the Open or...

Страница 20: ...the application of power 1 Check that the GS4000 power switch is off 2 Check that the breaker at the power panel is on 3 With a voltmeter on the proper scale check that the line voltage at terminals...

Страница 21: ...tact Sensor light comes on remains on until the connection is removed Observe that the both Motor Open and Motor Close lights are momentarily ON then the Motor Open light goes out and the Motor Close...

Страница 22: ...ment run the GS4000 open and closed several times to ensure that the positions set will be retained SMART SETTING MAXIMUM RUN TIMER The GS4000 is equipped with a Self adjusting MAximum Run Timer SMART...

Страница 23: ...LM IN BOTH DIRECTIONS OF TRAVEL REPEAT THIS TEST UNTIL YOU ARE SATISFIED YOU HAVE THE MOST SENSITIVE SETTING OF THE POTENTIOMETERS Disconnect the crank arm from the output shaft to permit re installat...

Страница 24: ...signs shipped with your GS4000 Operator See Figure 4 Page 5 of this manual must be installed in prominent positions on both sides of your gate Keep them clean and legible Read and put into practice th...

Страница 25: ...ontact sensors After adjusting the force or limits of travel retest the gate operator Failure to adjust and retest the gate operator properly can increase the risk of injury or death KNOW YOUR GATE AR...

Страница 26: ...26 1 2 3 4 5 7 6 8 9 10 11 12 13 14 15 16 17 18 19 20 106359 Figure 27 GS4000 Mechanical Unit Exploded View MECHANICAL UNIT EXPLODED VIEW...

Страница 27: ...HANDY BOX 1 7 8 DEEP 19 102735 HANDY BOX COVER WITH LABEL SCREWS 20 010231 CLUTCH DISC ITEM PART DESCRIPTION 1 109966 CONTROL BOX W COVER 2 110074 CONTROL BOARD 3 100997 CIRCUIT BREAKER 4 010412 ON O...

Страница 28: ...labor charges for dismantling or reinstalling a repaired or replaced unit or replacement batteries These warranties are in lieu of all other warranties either expressed or implied All implied warranti...

Отзывы: