W A R N I N G   H I G H   V O LTA G E

 

ONLY A QUALIFIED TECHNICIAN SHOULD SERVICE THIS GATE OPERATOR 

 

PERIODICALLY TEST SENSITIVITY OF OVERLOAD 

***  READ MANUAL  *** 

 

DATES 

DATE TESTED 

DATE TESTED 

DATE TESTED 

DATE TESTED 

SERVICED 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOG DATE OVERLOAD TEST 

 

Pre-Installation Notes................................................... 3 
 Operator 

Class 

Designation ................................... 3 

Section A:  Gate System Design/Installation ............. 4 
Section B:  Preparing the Site ..................................... 6 
 The 

Concrete 

Operator 

Pad.................................... 6 

  Placing the Vehicle Detector Loops  ..................... 6 
  Electrical Power Requirements.............................. 8  
Section C:  Installing the Operator ............................. 9 
  Placing the Mechanical Unit ................................. 10 
 Installing 

the 

Arm .................................................. 10 

  Installing the Control Box..................................... 11 
 Electrical 

Hookup .................................................. 11 

  Schematic and Wiring Diagram............................ 11 
  Wiring the Mechanical Unit and Control Box...... 12 
 Bi-Parting 

Wiring 

Diagrams.................................. 13 

 Accessory 

Equipment 

Hookup .................. 13,15,16 

 

  

 

READ THESE STATEMENTS CAREFULLY AND FOLLOW THE 

INSTRUCTIONS CLOSELY.

 

The Warning and Caution boxes throughout this manual are there to protect you and 

your equipment.  Pay close attention to these boxes as you follow the manual.

 

 

WARNING

 

Indicates a MECHANICAL 

hazard of INJURY OR 

DEATH. Gives instructions 

to avoid the hazard. 

CAUTION

 

Indicates a MECHANICAL hazard 

of DAMAGE to your gate, gate 

operator, or equipment. Gives 

instructions to avoid the hazard. 

Indicates an ELECTRICAL 

hazard of INJURY OR 

DEATH. Gives instructions 

to avoid the hazard. 

WARNING

 

Indicates an ELECTRICAL hazard 

of DAMAGE to your gate, gate 

operator, or equipment. Gives 

instructions to avoid the hazard. 

CAUTION

 

 TABLE OF CONTENTS 

  Pre-Setting the Motor Overload Sensitivity......... 17 
  Terminal Strip Reference Chart.....................17 - 19 
Section D:  Starting the Operator.............................. 19 
  Setting the Limit Switches .................................... 19 
  Setting the Switch Selectable Options ................ 19 
  No Load Test Mode................................................ 19 
 Applying 

Power...................................................... 20 

 Indicator 

Lamps ..................................................... 20 

 Maximum 

Run 

Timer.............................................. 22 

 Final 

Settings ......................................................... 22 

Section E:  Auxiliary Equipment ............................... 23 
Section F:  End User Instructions ............................. 24 
  Safety Guide for the End User.............................. 24 
  Operational Guide for the End User..................... 25  
Operator Exploded View & Parts List .............. 26 & 27 
Technical Specifications............................................ 28 

Figure 1:  Test Log     

Содержание ANSI/UL 325

Страница 1: ...for Vehicular gate operators GATE STAR 4000 Model GS4000 Heavy Duty Commercial Vehicular Swing Gate Operator READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE SAVE THESE INSTRUCTIONS 104950 Seria...

Страница 2: ...ere to protect you and your equipment Pay close attention to these boxes as you follow the manual WARNING Indicates a MECHANICAL hazard of INJURY OR DEATH Gives instructions to avoid the hazard CAUTIO...

Страница 3: ...cal parts Whether the overload is activated before the Torque Limiter slips will depend upon the tightness of the adjustment of the Torque Limiter This adjustment will be explained in the final check...

Страница 4: ...re a handhold or toehold may be achieved injuries may occur when people put arms through the openings or children ride the gate by standing on the bars and holding on to the gate THIS POTENTIAL HAZARD...

Страница 5: ...the GS4000 Control Box cover is removed high voltage will be exposed EVEN IF THE RED POWER LIGHT IS NOT LIGHTED HIGH VOLTAGE AC MAY STILL BE PRESENT ON TERMINALS L1 AND L2 NEVER LEAVE THE INSTALLATIO...

Страница 6: ...r attention to the bolt pattern and the location of the mounting holes with respect to the center line of the gate post It is critical for the proper operation of the Arm that the center line of the s...

Страница 7: ...O K DO NOT USE ANY PVC INSULATED WIRE PVC insulation will absorb moisture that may affect Detector operation WIRE SIZE SHOULD BE 16 GA STRANDED OR LARGER VEHICLE DETECTOR LOOP BLANKING FOR SWING GATES...

Страница 8: ...lt Amperes Watts IF TWO MECHANICAL UNITS ARE TO BE USED FOR A BI PARTING GATE SYSTEM THEN A 1000 VOLT AMPERE WATT TRANSFORMER MUST BE USED Operating from a three 3 phase line will require the use of a...

Страница 9: ...or connecting accessory equipment to the control box terminal strip and for limit switch control wires 7 Four 1 2 diameter concrete redhead bolts with hex nuts flat washers and lock washers For attach...

Страница 10: ...n accordance with the drawing of Figure 6 INSTALLING THE GS4000 ARM Temporarily locate the Gate Bracket on the Gate with C clamps or by tack welding Install the gate bracket to the gate so the gate ar...

Страница 11: ...t entry Run a flexible water tight conduit from the service junction box to the GS4000 CONTROL BOX Pull three 14 wires from the service junction box in this conduit to the GS4000 Control Box If the GS...

Страница 12: ...eriod of time is long enough to damage solid state components and many times other components The key to success is a very low resistance path from the surge protector to ground for these currents in...

Страница 13: ...tion one operator must be a Left Hand unit and the other a Right Hand unit The two motors of the Bi Parting GS4000 s will be wired in parallel BOTH motors will run until both are shut off If the two g...

Страница 14: ...14 C INSTALLING THE OPERATOR Figure 15 Bi Parting Installation Limit Motor Wiring Diagram 110092...

Страница 15: ...sary as the GS4000 control board 24 VAC output is not referenced to ground See Figure 16 and the following text for proper connection FOUR WIRE RECEIVERS Four wire receivers replace the spade terminal...

Страница 16: ...from a location where it will be switched off at the GS4000 Power Switch CONNECTING THE VEHICLE DETECTOR For a REVERSING LOOP connection of the Vehicle Detector the relay or presence output of the Det...

Страница 17: ...ME DESCRIPTION 1 24 VAC Provides maximum 10 VA auxiliary power for accessories 2 24 VAC Provides maximum 10 VA auxiliary power for accessories 3 ALTERNATE Momentary input must be released and re enter...

Страница 18: ...continuous signal This input is active only when referenced to the opening direction it has no effect on the gate when closing or about to close If activated when the gate is opening the gate will st...

Страница 19: ...operation as described in the text that follows OPEN CLOSE PUSH BUTTON ENABLE DISABLE PATENT NO 6 611 205 Switch S1 controls the Push Button Enable Disable Feature SWITCH 1 OFF Activating the Open or...

Страница 20: ...the application of power 1 Check that the GS4000 power switch is off 2 Check that the breaker at the power panel is on 3 With a voltmeter on the proper scale check that the line voltage at terminals...

Страница 21: ...tact Sensor light comes on remains on until the connection is removed Observe that the both Motor Open and Motor Close lights are momentarily ON then the Motor Open light goes out and the Motor Close...

Страница 22: ...ment run the GS4000 open and closed several times to ensure that the positions set will be retained SMART SETTING MAXIMUM RUN TIMER The GS4000 is equipped with a Self adjusting MAximum Run Timer SMART...

Страница 23: ...LM IN BOTH DIRECTIONS OF TRAVEL REPEAT THIS TEST UNTIL YOU ARE SATISFIED YOU HAVE THE MOST SENSITIVE SETTING OF THE POTENTIOMETERS Disconnect the crank arm from the output shaft to permit re installat...

Страница 24: ...signs shipped with your GS4000 Operator See Figure 4 Page 5 of this manual must be installed in prominent positions on both sides of your gate Keep them clean and legible Read and put into practice th...

Страница 25: ...ontact sensors After adjusting the force or limits of travel retest the gate operator Failure to adjust and retest the gate operator properly can increase the risk of injury or death KNOW YOUR GATE AR...

Страница 26: ...26 1 2 3 4 5 7 6 8 9 10 11 12 13 14 15 16 17 18 19 20 106359 Figure 27 GS4000 Mechanical Unit Exploded View MECHANICAL UNIT EXPLODED VIEW...

Страница 27: ...HANDY BOX 1 7 8 DEEP 19 102735 HANDY BOX COVER WITH LABEL SCREWS 20 010231 CLUTCH DISC ITEM PART DESCRIPTION 1 109966 CONTROL BOX W COVER 2 110074 CONTROL BOARD 3 100997 CIRCUIT BREAKER 4 010412 ON O...

Страница 28: ...labor charges for dismantling or reinstalling a repaired or replaced unit or replacement batteries These warranties are in lieu of all other warranties either expressed or implied All implied warranti...

Отзывы: