Not for
Reproduction
65
Maintenance
5-13
Clean element in sedimenter
Every 500 hours
1.
Turn the fuel selector valve
[A]
to the
[
OFF
]
position.
2.
Loosen the drain valve
[B]
and drain out condensed water
inside.
3.
Turn the cup
[C]
to the left and remove it. Wipe out the
inside of the cup.
4.
Remove the float
[D]
inside the cup
[C]
.
5.
Wash the element
[E]
and the inside of the cup
[C]
with
new fuel.
6.
Inspect the element
[E]
and O-ring (
[F]
&
[G]) for wear or
damage. Replace if needed
.
(For part number, See
“Replacement Parts.”)
7.
Assemble in the reverse procedure.
If air remains in the fuel line, set the CONTROL POWER
switch to
position and release the air by loosening
the bolt [H].
Drain the condensate into a container
[I]
, then dispose of
the condensate according to the designated regulations.
Check for cracks and leaks on the exhaust pipe
Every 500 hours
Inspect the flexible pipes in the exhaust system for
cracks or leaks etc.
Remove any insulating material wrapped around
pipes when performing inspection.
If any leak is found, take care to avoid getting
burned by exhaust gas.
After finishing inspection, rewrap the insulation and
tighten with with a clamp or belt.
A160708-1
A H
G
F
E
C
D
B
I
ON
OFF
Loosen
A180279
Exhaust flexible pipe
Heat insulator
Crack
Gas leak
DPF
Содержание Maxi-Air MA375-DP T4F
Страница 75: ...N o t f o r R e p r o d u c t i o n 75 Specifications 7 6 MA375 DP T4F A180444E...
Страница 76: ...N o t f o r R e p r o d u c t i o n 76 ALLMAND COM Specifications 7 7 MA400 T4F After cooler model A180445E...
Страница 77: ...N o t f o r R e p r o d u c t i o n 77 Specifications 7 8 MA375 DP T4F After cooler model A180447E...
Страница 78: ...N o t f o r R e p r o d u c t i o n 78 ALLMAND COM Specifications 7 9 Fuel Piping A180470E...
Страница 79: ...N o t f o r R e p r o d u c t i o n 79 Wiring Diagram...
Страница 80: ...N o t f o r R e p r o d u c t i o n 80 ALLMAND COM...
Страница 87: ...N o t f o r R e p r o d u c t i o n 87...
Страница 88: ...N o t f o r R e p r o d u c t i o n...