Not for
Reproduction
46 ALLMAND.COM
Operation
3-27
Manual regeneration
The exhaust temperature may not reach temperatures hot
enough to burn soot during operation in cold weather or under
low loads. If the unit is operated under low load or in cold
weather for an extended time, a DPF indicator [B] will be
displayed. Immediately take action and begin a Manual
Regeneration by following the steps below.
1.
Stop any ongoing work and close the service valve.
2.
Select “SYSTEM DIAGRAM” on the “HOME” screen and make sure that the water temperature is above
158°F (70
℃
)
If the water temperature is below 158°F (70
℃
), let the unit warm up until the water temperature is above
158°F (70
℃
).
3.
Press the DPF indicator [B] on the “MAIN” screen.
4.
The “PARKED REGENERATION” screen will be displayed.
5.
Hold the "REGEN" button to start manual regeneration. The High Exhaust System Temperature (HEST)
indicator [A] will be ON.
Note: It is normal for engine speed to vary while performing manual regeneration.
Regeneration will take anywhere from 15 to 30 minutes.
If the exhaust temperature is higher during regeneration, the High Exhaust System Temperature
(HEST) indicator [A] will be ON.
The DPF indicator [B] will be cleared once the manual regeneration is completed.
When finished, the unit will return to an unloaded state and be ready for normal operation.
Do not stop the engine during the manual regeneration.
Only begin manual regeneration after the engine is warmed up. If the water temp is not
enough high enough the unit will cancel the manual regeneration, as it may only
further clog the DPF if performed cold.
If the DPF indicator is ON, take immediate action to perform the manual regeneration.
Failure to do so could result in damage to the DPF or a fire in the exhaust system.
B
A
B
Содержание Maxi-Air MA375-DP T4F
Страница 75: ...N o t f o r R e p r o d u c t i o n 75 Specifications 7 6 MA375 DP T4F A180444E...
Страница 76: ...N o t f o r R e p r o d u c t i o n 76 ALLMAND COM Specifications 7 7 MA400 T4F After cooler model A180445E...
Страница 77: ...N o t f o r R e p r o d u c t i o n 77 Specifications 7 8 MA375 DP T4F After cooler model A180447E...
Страница 78: ...N o t f o r R e p r o d u c t i o n 78 ALLMAND COM Specifications 7 9 Fuel Piping A180470E...
Страница 79: ...N o t f o r R e p r o d u c t i o n 79 Wiring Diagram...
Страница 80: ...N o t f o r R e p r o d u c t i o n 80 ALLMAND COM...
Страница 87: ...N o t f o r R e p r o d u c t i o n 87...
Страница 88: ...N o t f o r R e p r o d u c t i o n...