Chapter 1: Overview
26
You may set the wiring configurations of the ports manually or let the
switch configure them automatically with auto-MDI/MDI-X (IEEE 802.3ab-
compliant). This feature enables the switch to automatically negotiate with
network devices to establish their proper settings.
The MDI and MDI-X settings do not apply when ports are operating at
1000 Mbps.
Maximum
Distance
The ports have a maximum operating distance of 100 meters (328 feet).
Cable
Requirements
The cable requirements of the ports are given in Table 1.
Note
For the cable requirements for the ports on the AT-x510-28GPX,
AT-x510L-28GP, AT-x510-52GPX, and AT-x510L-52GP Switches
for PoE devices, refer to Table 3 on page 28.
Port Pinouts
Refer to Table 19 on page 134 and Table 20 on page 134 for the port
pinouts of the 10/100/1000Base-T twisted pair ports.
Table 1. Twisted Pair Cable for the 10/100/1000Base-T Ports
Cable Type
10Mbps
100Mbps
1000Mbps
Standard TIA/EIA 568-B-
compliant Category 3 shielded
or unshielded cabling with 100
ohm impedance and a
frequency of 16 MHz.
Yes
Yes
No
Standard TIA/EIA 568-A-
compliant Category 5 or TIA/
EIA 568-B-compliant Enhanced
Category 5 (Cat 5e) shielded or
unshielded cabling with 100
ohm impedance and a
frequency of 100 MHz.
Yes
Yes
Yes
Standard TIA/EIA 568-B-
compliant Category 6 or 6a
shielded cabling.
Yes
Yes
Yes
Содержание AT-x510-28GPX
Страница 10: ...Tables 10 ...
Страница 14: ...Preface 14 ...
Страница 48: ...Chapter 1 Overview 48 ...
Страница 70: ...Chapter 3 Beginning the Installation 70 ...
Страница 84: ...Chapter 4 Installing the Switches on a Table or in an Equipment Rack 84 ...
Страница 128: ...Chapter 9 Troubleshooting 128 ...
Страница 138: ...Appendix A Technical Specifications 138 ...