Chapter 4: Installing the Switches on a Table or in an Equipment Rack
80
Warning
The power input must be provided by a SELV source only, per
IEC60950. Do not connect to a centralized DC battery bank.
E31
1. Use a 3mm flat-head screwdriver to loosen the two captive screws that
secure the DC connector to the chassis. Refer to Figure 33.
Figure 33. Loosening the Two Captive Screws on the DC Connector
2. Slide the DC connector from the chassis. Refer to Figure 34.
Figure 34. Removing the DC Connector
3. Use a 3mm (0.125 in.) flat-head screwdriver to loosen the two captive
screws on the top of the DC connector. Refer to Figure 35 on page 81.