Global Menu List Options
Display
Description
Default
AUDIO SIGNAL
Program the audio signal on or off for
keypad presses, end-of-cycle, coin/card
input, serial/network vend command and
29 (On for all except end-of-cycle)
NETWORK NODE NUMBER
1 - 250
250
ERRORS
Enable/disable and set the range of ma-
chine errors.
-
BACK
Return to higher menu.
-
COIN ERROR
If enabled, this error will display when in-
valid coin pulses are recorded.
-
BACK
Return to higher menu.
-
ENABLE
ENABLE/DISABLE
ENABLE
PENALTY
If enabled, all previous coin entries are
erased.
DISABLE
VEND HEADER PRESENT ERR
Set the control to ignore coin pulses trig-
gered when attaching and detaching a coin
drop.
ENABLE
FILL ERROR
If enabled, this error will display if the de-
sired fill level isn't reached within the pro-
grammed time.
-
BACK
Return to higher menu.
-
ENABLE
ENABLE/DISABLE
ENABLE
TIME
2 - 59 minutes
30 minutes
NO WATER FLOW ERROR
If enabled, this error will display if four
(4) inches of water is not reached within
the programmed time.
-
BACK
Return to higher menu.
-
ENABLE
ENABLE/DISABLE
ENABLE
TIME
1 - 59 minutes
5 minutes
DRAIN ERROR
If enabled, this error will display when the
water height is not below the empty level
after attempting to drain for the program-
med time.
-
BACK
Return to higher menu.
-
ENABLE
ENABLE/DISABLE
ENABLE
TIME
1 - 59 minutes
5 minutes
Table 15
continues...
Globals Menu
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
37
Part No. 806526ENR2
Содержание Quantum Platinum