Global Menu List Options
Display
Description
Default
WATER LEAK DETECT ERROR
If enabled, this error will test if the water
level has raised more than an acceptable
amount.
-
BACK
Return to higher menu.
-
DAY(S) OF WEEK ENABLE
0 - 255
0
NUMBER OF CYC BETWEEN
0 - 127
10
DISPLAY SEQUENCE
ENABLE/DISABLE
ENABLE
SLOW DRAIN DETECT ERROR
If enabled, this error will display if the
time it takes for the water level to drop is
longer than the specified time.
-
BACK
Return to higher menu.
-
ENABLE
ENABLE/DISABLE
DISABLE
ADJUSTMENT
0 - 255 seconds
0 seconds
NON-FATAL UNBAL ERROR
ENABLE/DISABLE
DISABLE
SUDS LOCK ERROR DISPLAY
ENABLE/DISABLE
DISABLE
SUDS REMOVAL
If enabled and excessive suds are detected
during a cycle, the control will start a spe-
cial routine designed to help eliminate
suds.
-
BACK
Return to higher menu.
-
DISPLAY
ENABLE/DISABLE
DISABLE
ROUTINES ALLOWED PER CYC
0 - 10
1
EXTRA TIME
ENABLE/DISABLE
ENABLE
OVERFLOW MODE DISPLAY
ENABLE/DISABLE
ENABLE
ALLOW ERROR CLEARING
ENABLE/DISABLE
ENABLE
WATER LEVEL
Set global water levels for each fill level.
-
BACK
Select to return to higher menu.
-
LOW WATER LEVEL
1 - 30 (5.4 - 8.3 in. [137 - 211 mm])
6 (5.9 in. [150 mm]
MEDIUM WATER LEVEL
1 - 30 (5.4 - 8.3 in. [137 - 211 mm])
10 (6.3 in. [160 mm]
HIGH WATER LEVEL
1 - 30 (5.4 - 8.3 in. [137 - 211 mm])
15 (6.8 in. [173 mm]
FLUSH OUT TIME FOR FILLS
0 - 255 seconds
25 seconds
NO REFILL TIME AGITATE STEP
0 - 255 minutes
255 minutes
REAL-TIME CLOCK
Set the time within the control.
-
Table 15