Two Drain Valves
C-CZW6NB
1
1, 2
1
1
3
1
2
A
1.
Drain outlet (Bottom)
2.
Drain outlet (Recycle Bottom - optional)
3.
Clamp
4.
Waste pipeline
Figure 23
Drain Requests
Specification
in. [mm]
A
19.68 [500]
Table 16
Main Drain Channel-pipe
The main drain channel-pipe must have the capacity to be able to
handle the total output of all connected machines. In a drain pipe,
a vent must be provided every 787.4 in. [20 m] to assure the good
working of the drain pipe. Refer to
.
If the main drain pipe cannot be sufficiently vented, install a vent
per machine. Every time a machine is coupled on the drain pipe,
the diameter of the tube or the width of the waste channel must
be more. Refer to
.
Recommended Drain Pipes Diameter
Specification
in. [mm]
One Machine
A
5.9 [150]
Two Machines
B
7.08 [180]
Three Machines
C
7.87 [200]
Table 17
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
34
Part No. D2601EN