Toolbox Menu
Display Message
Information
View Input States ?
1 Input 1 On
…
20 Input 20 Off
The Input states for Input 1, …, Input 20.
The exact function of the inputs can be found on the electrical drawing of the
washing machine programmer.
• If the Input state is Off, the Input signal is low.
• If the input state is On, the Input signal is high.
Imbalance Statistics …
Imbalance …
1 ...0.5 0
...
31 > 15 0
Current …
1 I0 0
...
4 I3 0
Diagnostic information on imbalance of the machine.
Inverter Power Off
By this function it‘s possible to switch on the power of the inverter if a tech-
nical intervention is needed.
NOTE: Special care has been taken at the initialization of the pa-
rameters of the frequency inverter. The manufacturer is not re-
sponsible for the wrong behavior of the washing machine if the
owner has installed new parameter settings in the inverter that
do not correspond with the original settings at the factory.
Reset Service Counts No
Once the washing machine has reached the total number of wash cycles like
set at the "Service Interval" a warning is given at the end of each cycle until
the Cycle Counter has been reset.
RTC Time XX:YY:ZZ
The Time value of the Real Time Clock.
XX : Hours, YY : Minutes, ZZ : Seconds
RTC Date AA:BB:CC
The Date value of the Real Time Clock.
AA : Day, BB : Month, CC : Year
Adjust Clock …
Hour XX
Minutes YY
Day AA
Month BB
Year CC
Set the correct Date and Time for the RTC.
Table 49
continues...