Failure Message Overview
Num-
ber
Failure Mes-
sage
Failure
Action
Fault Occurrence
E10
Temp. Not Reached Target temp. not reachet
Full stop + tumble
Wash step
E11
No Fill
Fill failure
Full stop + request for Contin-
ue
While filling
E12
OverFill
Overfill failure
Full stop + tumble
While filling
E13
No Heating
Heating failure
Full stop + tumble
While heating
E14
Heat. Time
Heating time failure
Full stop + request for continue While heating
E15
Too Hot
Too Hot
Full stop + tumble
While heating
E16
Coin blocking 1
Coin meter failure
/
Before start up
E17
Coin blocking 2
Coin meter failure
/
Before start up
E18
Door Lock Pre-test
Door check before start failure
Don´t start
Before start up
E19
Door Lock Start
Door check at start failure
Don´t start
At start up
E21
OverFlow
Overflow failure
Full stop + tumble
Wash step
E24
Level Sens
Defective level sensor
Co Don’t start
Before start up
E25
Temp Sensor
Defective temperature sensor
Co Don’t start
Before start up
E26
Mitsub. Code
Undefined frequency inverter
error code
Full stop + tumble
Whole cycle
E27
Comm fault
Communication fault inverter
Full stop + safety time
Whole cycle
E28
THT time / E.OL
THT Time out / E.OL
Full stop + safety time
At spin sequence
E29
OV3 time / E.OP
OV3 Time out / E.OP
Full stop + safety time
At spin sequence
E31
Load Par
Initialization fault inverter
Don’t start
At initialization
E32
Verify Par
Verification fault inverter
Don’t start
At loading parameters
E35
Wrong Softw
Wrong software version
Don’t start
New software version
E36
Imbalance
Unbalance detection system ac-
tivated.
Reduction of spinning se-
quence revolutions. For Infor-
mation only.
Spinning sequence
E37
No Drain Spr
Drain failure at the Spray Se-
quence
Full stop + tumble
Spray Sequence
E39
Out of Soap
The Soap Supplies are running
Out of Soap
For Information only
Wash step
E41
Service Due
Service Due Warning
For Information only Open
door = reset
End cycle
E42
Connection
No Network Connection
For Information only
Data Transfer Networking
E43
Voltage Par
Wrong Voltage Range Selection Make correct selection
Configuration menu
Table 47
continues...
Troubleshooting
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
80
Part No. D1631ENR7
Содержание IYG065J