52. EXHAUST DUCT
a. Disconnect electric power, vent (and gas line if
necessary) and move unit to gain access to rear
of dryer.
b. Remove front panel. Refer to Paragraph 31,
steps “a” through “c”.
c. Remove one hex head screw holding bracket on
exhaust duct to rear of cabinet.
d. Pull duct out through rear of cabinet.
53. EXHAUST FAN COVER
a. Remove front panel. Refer to Paragraph 31,
steps “a’ through “c”.
b. Remove lint filter. Refer to Figure 19.
c. Remove hex head screws holding air duct to
front bulkhead and lift off. Refer to Figure 28.
NOTE: When reassembling, be sure felt seal on
exhaust fan cover makes air tight seal on flange of
air duct. Refer to Figure 29.
d. Disconnect wires from thermostats.
NOTE: Refer to appropriate wiring diagram when
rewiring thermostats.
e. Remove hex head screw holding ground wire to
exhaust fan cover. Refer to Figure 29.
NOTE: Ground wire must be rerouted as shown in
Figure 29. (Refer to Section 2, Grounding.)
f. Remove hex head screws holding cover to
housing. Refer to Figure 29.
54. MOTOR AND EXHAUST ASSEMBLY
a. Remove front panel. Refer to Paragraph 31,
steps “a’ through “c”.
b. Remove lint filter. Refer to Figure 19.
c. Remove hex head screws holding air duct to
front bulkhead and lift off. Refer to Figure 28.
NOTE: When reassembling, be sure felt seal on
exhaust fan cover makes air tight seal on flange of
air duct. Refer to Figure 29.
d. Disconnect wires from thermostats.
NOTE: Refer to appropriate wiring diagram when
rewiring thermostats.
e. Remove cylinder belt from idler and motor
pulleys.
f. Remove two screws holding motor mounting
bracket to dryer base. Refer to Figure 29. Then
pull complete assembly out through front of
dryer.
g. Disconnect wires from motor switch.
NOTE: Refer to appropriate wiring diagram when
rewiring motor switch.
IMPORTANT: When reinstalling motor and
exhaust assembly, be sure wire harness on right side
is clipped to motor mounting bracket and is routed
along dryer base (between motor mounting bracket
and right side of cabinet). Refer to Figure 29. Tab on
rear of motor mounting bracket must be slid into
slot in dryer base. Exhaust duct MUST BE