To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
31. FRONT PANEL AND PANEL SEAL
Refer to Figure 21
a. Remove two screws from bottom edge of front
panel.
b. Swing bottom of panel away from dryer to
disengage hold-down clips and guide lugs from
cabinet top.
c. Disconnect wires from door switch (refer to
appropriate wiring diagram when rewiring
switch).
d. Remove front panel seal from flange around
inside of door opening.
NOTE: Be sure seal is positioned properly when
replacing.
32. BURNER HOUSING
a. Remove front panel. Refer to Paragraph 31,
steps “a” through “c”.
b. Close gas shutoff valve and disconnect wires
from sensor and disconnect blocks. Refer to
Figure 14.
c. Loosen union nut between gas shutoff valve
and nipple connector to gas valve. Unthread nut
from nipple complete. Refer to Figure 14.
d. Remove screws holding valve and bracket to
base. Refer to Figure 14.
e. Lift gas valve and mounting bracket from base
and carefully remove out through front of dryer.
f. Remove screw from right side of burner
housing holding burner tube in place. Refer to
Figure 14.
g. Gently move burner tube toward rear of dryer to
disengage tab from slot on left side of burner
housing. Refer to Figure 16.
h. Carefully rotate burner tube and igniter
counterclockwise to tab is at 8 o’clock position.
i. Move air shutter end of burner tube slightly to
right and CAREFULLY remove burner tube
and igniter assembly out through front of dryer.
j. Remove hex head screw holding burner
housing to heat shroud. Refer to Figure 16.
k. Remove hex head screw holding front of burner
housing to dryer base and remove housing out
through front of dryer.
To Test Electrical Circuit to Ignition System:
1. Remove access door and close gas shut-off
valve.
2. Disconnect valve wire harness from dryer
harness at molex plug.
3. Plug dryer power cord into wall receptacle, set
FABRIC switch and timer into positions calling
for heat and start dryer.
4. Set test meter to read AC voltage and apply
meter probes into PINK and WHITE wire
terminals on dryer harness side of molex plug.
Meter should register line voltage in all
FABRIC settings, except FLUFF which should
read “zero” VAC.
5. If meter does not register as explained in step
“4”, check motor switch and timer motor circuit.
Use care in removal so as not to damage or
break igniter as it is very fragile.