34
53264
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
41. DOOR HINGE AND SUPPORT BRACKET
a. Open loading door and remove four screws
holding door assembly to hinges. Refer to
Figure 19.
b. Remove front panel. Refer to Paragraph 31,
steps “a” through “c”.
c. Remove four Phillips head screws and locknuts
holding hinges to front panel. Refer to
Figure 21.
NOTE: Through Serial No. S70U4371, support
bracket is removed with lower hinge. Support
bracket must be installed when reassembling.
42. HOLD-DOWN CLIPS AND GUIDE LUGS
Refer to Figure 21
a. Remove front panel. Refer to Paragraph 31,
steps “a” through “c”.
b. Compress hold-down clips and remove from
slot in top flange of front panel.
c. Remove four screws holding four guide lugs to
front panel.
Figure 21
DRY851S
GUIDE
LUG
STRIKER
CATCH
ACCESS
DOOR
DOOR
HINGE
PHILLIPS
HEAD SCREWS
HEX
HEAD SCREW
LOCKNUT
SUPPORT BRACKET
(Through Serial No.
S70U4371)
FRONT
PANEL SEAL
DOOR
SWITCH
HOLD-DOWN
CLIP