53264
53
Section 7 Gas Burner Conversion Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
s. Connect electrical service and open valve in gas
supply line. Start dryer and observe burner
flame. Adjust air shutter to obtain a soft,
uniform flame. (A lazy, orange tipped flame
indicates lack of air. A harsh, roaring, very blue
flame indicates too much air.) Adjust air shutter
to obtain a soft uniform blue flame as follows:
(1) Loosen air shutter lockscrew.
(2) Turn air shutter to the right or left as
necessary to obtain proper flame intensity.
(3) After air shutter is adjusted for proper
flame, tighten air shutter lockscrew
securely.
t. Be sure and observe at least two complete
ignition and burn cycles before reinstalling
access door.