46
53264
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
64. HEAT SHIELD
a. Remove front panel. Refer to Paragraph 31,
steps “a” through “c”.
b. Remove cylinder assembly. Refer to Paragraph
60, steps “b” through “e”.
c. Gas Models – Remove burner housing. Refer to
Paragraph 32, steps “b” through “j”.
d. Gas Models – Remove four hex head screws
holding heat shroud to heater box. Refer to
Figure 16. Remove shroud out through front of
dryer.
e. Electric Models – Remove two hex head screws
holding element and plate to heater box. Pull
element down and away from heater box. Refer
to Figure 25.
f. Electric Models – Disconnect wires from
element terminals and from high limit
thermostat.
NOTE: When reassembling, be sure all wire
connections are tight on element terminals and to
high limit thermostat.
g. Remove two hex head screws holding heater
box to heat shield. Refer to Figure 37.
h. Disconnect vent and move dryer to gain access
to rear of dryer.
i. Remove two hex head screws holding heat
shield to rear of dryer cabinet. Refer to
Figure 40.
65. REAR MOUNTING BRACKETS
a. Remove front panel. Refer to Paragraph 31,
steps “a” through “c”.
b. Remove cylinder assembly. Refer to Paragraph
60, steps “b” through “e”.
c. Gas Models – Remove burner housing. Refer to
Paragraph 32, steps “b” through “j”.
d. Gas Models – Remove four hex head screws
holding heat shroud to heater box. Refer to
Figure 16. Remove shroud out through front of
dryer.
e. Electric Models – Remove two hex head screws
holding element and plate to heater box. Pull
element down and away from heater box. Refer
to Figure 25.
f. Electric Models – Disconnect wires from
element terminals and from high limit
thermostat.
NOTE: When reassembling, be sure all wire
connections are tight on element terminals and to
high limit thermostat.
g. Remove two hex head screws holding heater
box to heat shield. Refer to Figure 37.
h. Remove one Phillips head screw holding rear
bulkhead to terminal block bracket. While
supporting bulkhead, remove the four Phillips
head screws holding rear bulkhead to mounting
brackets. Refer to Figure 37. Lift complete
assembly out of dryer.
i. Remove five screws holding rear mounting
brackets to rear of dryer cabinet. Refer to
Figure 40.
Figure 40
DRY867S
HEAT SHIELD
ATTACHING
SCREWS
(if present)
REAR MOUNTING
BRACKET ATTACHING
SCREWS
GROUND
SCREW