Troubleshooting Coin Drop
Is proper electrical
power supplied to
coin drop? (Incorrect
electrical connection
may prevent coins
from registering in
coin drop.)
Is machine level?
(Machines that aren't
level may prevent
coins from following
through required
check stages of drop.)
Yes
Refer to wiring
diagram for proper
connections.
No
Is coin drop clean?
(Residue or lint
build-up may prevent
coins from following
through required
check stages of drop.)
Yes
Refer to Installation
Instructions for
instructions on
leveling machine.
No
Do coins fall freely
through drop?
Yes
Refer to Adjustments
section for
instructions on
cleaning drop.
No
Replace coin drop.
No
Electronic Coin Drops
.
2. On electronic coin drops with an old-style tension spring
(shown in
spring using the following instructions.
Remove Coin Drop From Machine
1. Disconnect electrical power to machine and drop.
2. Remove coin drop from machine.
Test Tension Spring
1. Push coin return button to open and close coin drop cover to
clear possible coin jams.
MIX7B_SVG
3
2
1
1.
Coin Return Button
2.
Coin Drop Cover
3.
Tension Spring
Figure 4
2. Manually hold down coin drop cover and insert coin.
MIX6B_SVG
1
1.
Coin Drop Cover
Figure 5
3. If coin drop now operates properly, replace tension spring us-
ing instructions that follow.
Replace Tension Spring
1. Move tension spring downward until cover catch is free. Re-
.
General Troubleshooting
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
14
Part No. 204591EN