Cleaning Non-Electronic Coin Drop
1. Disconnect electrical power to machine and drop.
2. Remove coin drop from machine.
3. If lint is preventing coins from rolling through coin drop,
blow compressed air though coin entry and along the side of
the coin drop. Refer to
.
DRY3B_SVG
3
2
1
1.
Compressed Air
2.
Cotter Pin
3.
Metal Clip
Figure 13
4. Insert a coin through the coin drop. If coin does not roll
through drop, continue with the following.
5. Remove cotter pin from top of drop. Refer to
. Save
pin for reinstallation when cleaning is complete.
6. Move metal clip closer to sensor so that it comes off frame.
Refer to
7. Remove coin return from coin drop frame. Refer to
.
DRY4B_SVG
2
1
1.
Coin Return
2.
Coin Drop Frame
Figure 14
8. Check coin path in coin drop for lint and residue. If lint or
light residues are present, use a cotton swab to remove. If
heavy residue is present, it may be necessary to first scrape
off excessive residue and then use a cotton swab dipped in
water or isopropyl alcohol (rubbing alcohol) to remove re-
mainder of residue. Refer to
.
DRY5B_SVG
1
1.
Cotton Swab
Figure 15
9. Check coin return pendulum to verify it swings freely. If pen-
dulum does not swing freely, spray pendulum pivot point with
Teflon based lubricant and move pendulum back and forth
two to three times. An additional application of Teflon based
lubricant may be necessary to ensure that pendulum swings
freely. Refer to
.
DRY6B_SVG
2
1
1.
Pendulum
2.
Pivot Point
Figure 16
10. Check coin drop sensor for dust or dirt on eyes. Wipe eyes
with dry cotton swab. Refer to
.
IMPORTANT: DO NOT use isopropyl alcohol to
clean electronic sensor or eyes.
Adjustments
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
58
Part No. 204591EN