Error Codes
Display
Description
Cause/Corrective Action
E dS
Brownout/Voltage
Configuration
Unexpected supply voltage. Check the harness connections between the user control
and the output board. If the user control was replaced, set dip switch #1 to the same
seting as the previous control. If reworking the machine to use a different voltage sup-
ply, the dip switch #1 setting may need to be changed. If the dip switch #1 setting is
changed, power down, power up and try again.
E nr
Drive/Output
Board Not Ready
Hardware failure. Try cycling power to machine before replacing output board.
E bS
Drive/Output
Board Shorted
Hardware failure. Try cycling power to machine before replacing output board.
En
Machine ID Errors
En 31
Product Byte #1
Mis-Match
Product family does not match between the Machine ID Control and Front End Con-
trol. Replace Machine ID Control with one meant for current Front End Control plat-
form.
En 32
Product Byte #2
Mis-Match
Machine type does not match between the Machine ID Control and Front End Control
(frontload washer vs. dryer). Replace Machine ID Control and/or front end control
with one meant for current machine type.
En 33
Product Byte #3
Mis-Match
Control level does not match between the Machine ID Control and Front End Control
(A4 vs. A2). Replace Machine ID Control with a properly configured A level for the
control being attached. Use Factory Test Procedure to determine front end control’s
control level.
En 39
Corrupted Data on
Machine ID Con-
trol
Try cycling power to machine. If error continues, check for damage to Machine ID
Control and harness and/or replace Machine ID Control with a correctly configured
Machine ID Control.
En 3E
Machine control
cannot be config-
ured with the Ma-
chine ID Control
in the machine
Try cycling power to machine. If error continues, check for damage to Machine ID
Control and harness and/or replace Machine ID Control with a correctly configured
Machine ID Control.
En 3F
Cannot communi-
cate with the Ma-
chine ID Control
Try cycling power to machine. If error continues, check for damage to Machine ID
Control and harness and/or replace Machine ID Control with a correctly configured
Machine ID Control.
E Co
Drive/Output
Board Comunica-
tion Error
Communication failure. Power down, power up and try again. If error persists, check
connection between user control and output board, or try replacing the user control or
the output board.
E dr
Drain Error
If the control has the drain error enabled the control will enter Machine Error Mode
when the water height is not below the empty level, after attempting to drain for the
programmable time (default 15 minutes). In the event of a drain error, the control will
turn off all outputs and turn on the Machine Error Tone for 15 seconds.
Table continues...
Troubleshooting Electronic Control
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
42
Part No. 204591EN