Factory Test Cycle Quick Reference Chart
Display
Test Mode
Comments
Pd
Power Down
This is the final step of Factory Test. The
control will display
Pd
to signify that
factory test has been completed and that
the user can safely unplug the machine.
Cycling power to the machine is the only
way to resume normal operation and the
control will stay in this state indefinitely
until that time.
Table 1
Clicking Noise During Operation on
NEWLY Installed Units
If a clicking noise is heard when first starting up a new topload
washer, the noise is related to the belt taking a temporary “set”
around the idler pulley. The set causes a slight bump in the belt
which in turn causes the idler lever to tap the motor bracket mak-
ing the clicking noise. THE BELT DOES NOT NEED TO BE
REPLACED.
To correct this condition please perform the following break-in
procedure:
1. After installing the unit start a fill cycle to make sure the seals
have been lubricated.
2. Stop the fill cycle and place the unit into a spin cycle.
3. Run the cycle for several minutes until the belt has warmed
up. This will remove the “set.”
4. Normal use will keep the belt from resetting.
5. For extended periods of non-use (three to four weeks), this
procedure might need to be repeated.
Troubleshooting Coin Drop
Non-Electronic Coin Drops
When coin is placed into coin slot, the coin should roll down
drop and be heard dropping into coin vault. If coin does not fall
into coin vault or if coin drop sensor does not register that coin
has been entered, follow troubleshooting instructions on follow-
ing page. Refer to
for path that coin follows when work-
ing properly.
IMPORTANT: Never use oil to correct coin drop prob-
lems. Oil residue will prevent coins from rolling proper-
ly.
IMPORTANT: Do not bend or damage mechanical parts
within coin drop.
DRY2B_SVG
3
2
1
1.
Coin Drop Sensor
2.
Additional coins following path to sensor
3.
Coin in Coin Slot
Figure 3
General Troubleshooting
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
13
Part No. 204591EN