M413487
23
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Section 5
Service Procedures
20. ACCESS PANEL/CONTROL BOX
a. Remove four screws holding access panel to
cabinet. Refer to Figure 1.
b. Lift access panel off top edge of front panel and
pull panel forward. Refer to Figure 1.
c. Remove control box cover. Refer to Figure 2.
21. FRONT PANEL
a. Remove four screws holding access panel to
cabinet. Refer to Figure 1.
b. Lift access panel off top edge of front panel and
pull panel forward. Refer to Figure 1.
c. Remove control box cover. Refer to Figure 2.
d. Remove four screws from timer graphic panel.
Disconnect timers and door switch wires at
molex plugs. Set aside timer graphic panel to
prevent damage. Refer to Figure 4.
e. Loosen set screw on temperature knob, and
remove knob from temperature graphic panel.
f. Remove two screws holding thermostat to
temperature graphic panel.
g. Remove four screws from temperature graphic
panel, then disconnect reversing/nonreversing
switch, load ready light, and low airflow light.
Set aside temperature graphic panel to prevent
damage.
h. Open and remove lint panel. Set aside to
prevent damage.
i. Open loading door, support door and remove
both hinge pins holding door to hinge brackets.
Refer to Figure 3.
NOTE: Nylon washer must be in place above lower
hinge bracket when reinstalling door.
j. Remove door from hinge brackets.
k. Support front panel and remove screws holding
front panel to tumbler cabinet. Refer to
Figure 3.
l. Remove front panel while carefully feeding
door switch wires through hole in cabinet.
NOTE: Refer to wiring diagram when rewiring
lights and switch.
Figure 1
TMB1498S
ACCESS PANEL
ATTACHING
SCREWS
ACCESS
PANEL
THERMOSTAT
PANEL
TIMER BOX
COVER
TIMER
PANEL