26
M413487
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
25. COOLING AND DRYING TIMERS
(Manual Timer Models)
a. Remove four screws holding access panel to
cabinet. Refer to Figure 1.
b. Lift access panel off top edge of front panel and
pull panel forward. Refer to Figure 1.
c. Remove timer box cover. Refer to Figure 1.
d. Pull timer knob off timer shaft. Refer to
e. Remove wires from timer terminals.
f. Remove three screws holding timer to timer
graphic panel.
NOTE: Refer to wiring diagram when rewiring
timer.
Figure 4
10
20
30
40
50
60
10
15
5
0
0
TMB1337P
PUSH-TO-START
SWITCH
RELAY
MOUNTING
SCREW
RELAY
COOLING
TIMER
WIRE
LEADS
COOLING
LIGHT
IGNITION
RESET
SWITCH
TIMER
GRAPHIC
PANEL
START
SWITCH
MOUNTING
SCREW
DRYING
TIMER
WIRE
LEADS
RUN
LIGHT
TIMER
MOUNTING
SCREW
TIMER
KNOBS