42
M413487
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
55. FAN BELT
Refer to Figure 19.
a. Support corner drive guard and remove screws
holding corner guard to rear of tumbler. Refer
to Figure 13.
b. Support drive guard cover and remove screws
holding guard to rear of tumbler. Refer to
Figure 13.
c. Loosen fan belt with adjusting nuts. Refer to
d. Remove fan belt.
NOTE: After reinstalling fan belt, adjust belt
tension.
56. FAN MOTOR PULLEY
a. Support corner drive guard and remove screws
holding corner guard to rear of tumbler. Refer
to Figure 13.
b. Support drive guard cover and remove screws
holding guard to rear of tumbler. Refer to
Figure 13.
c. Loosen fan belt with adjusting nuts. Refer to
d. Remove fan belt. Refer to Figure 19.
e. Loosen setscrews and remove screws from
tapered bushing.
f. Remove tapered bushing by putting the screws
removed in step “e” into the threaded holes in
the bushing. Turning the screws inward will
force the bushing out of the motor pulley.
g. Remove fan motor pulley. Refer to Figure 19.
57. FAN PULLEY
Refer to Figure 19 or Figure 20.
a. Support corner drive guard and remove screws
holding corner guard to rear of tumbler. Refer
to Figure 13.
b. Support drive guard cover and remove screws
holding guard to rear of tumbler. Refer to
Figure 13.
c. Loosen fan belt with adjusting nuts. Refer to
d. Remove fan belt.
e. Loosen setscrew and remove screws from
tapered bushing.
f. Remove tapered bushing by putting the screws
removed in step “e” into the threaded holes in
the tapered bushing. Turning the screws inward
will force the bushing off of the tapered
bushing.
g. Remove tapered bushing and fan pulley from
blower shaft.
58. FAN MOTOR
Refer to Figure 19.
a. Support corner drive guard and remove screws
holding corner guard to rear of tumbler. Refer
to Figure 13.
b. Support drive guard cover and remove screws
holding guard to rear of tumbler. Refer to
Figure 13.
c. Loosen fan belt with adjusting nuts. Refer to
d. Remove fan belt.
e. Remove fan motor pulley.
f. Remove screws holding fan motor to motor
base.
g. Disconnect wires from motor.
NOTE: Refer to wiring diagram when rewiring
motor.
h. Remove fan motor.