36
M413487
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
39. STEAM COILS
Refer to Figure 11
a. Shut off inlet and outlet valves and disconnect
flex hoses from steam coils
b. Remove screws holding cover to top of steam
heating unit and remove cover.
c. Remove air filters.
d. Remove screws holding steam coils to coil
frame.
e. Remove screws from damper.
f. Remove steam coils by lifting straight up and
out of tumbler.
IMPORTANT: When removing or replacing steam
coils, be careful not to damage fins on steam coils.
40. LOADING DOOR ASSEMBLY
Refer to Figure 3
a. Open loading door.
b. While supporting door, remove upper and
lower hinge pins holding door to hinge
brackets.
c. Remove door from hinge brackets.
NOTE: Nylon washer must be in place above lower
hinge bracket when reinstalling loading door.
41. LOADING DOOR HINGE BRACKETS
NOTE: If both the upper and lower door hinge
brackets are removed at the same time, the door
switch bracket will fall inside the tumbler. The front
panel will have to be removed to retrieve the door
switch bracket. In order to avoid this problem,
change door hinge brackets only one at a time.
a. Open loading door.
b. While supporting door, remove upper and
lower hinge pins holding door to hinge
brackets.
c. Remove door from hinge brackets.
d. Remove screws holding brackets to front panel.
42. LOADING DOOR HINGES
Refer to Figure 3.
a. Open loading door.
b. While supporting door, remove upper and
lower hinge pins holding door to hinge
brackets.
c. Remove door from hinge brackets.
d. Remove screws holding hinges to door.
e. Remove door switch actuator from upper hinge.
NOTE: Door switch actuator must be reinstalled in
upper hinge when door is reassembled.
43. LOADING DOOR HANDLE
Refer to Figure 3.
a. Open loading door.
b. Remove screws holding door handle to door
frame.
Figure 11
T244PE1A
STEAM
HEATING UNIT
COVER
AIR
FILTER
STEAM
COILS
DAMPER