M413487
37
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
44. LOADING DOOR SWITCH
a. Remove front panel.
b. Disconnect wires from door switch.
c. Remove two switch attaching screws and
remove switch. Refer to Figure 12.
NOTE: Refer to wiring diagram when rewiring
door switch.
45. DRIVE GUARD COVER / CORNER DRIVE
GUARD
Refer to Figure 13.
a. Support corner drive guard and remove screws
holding corner guard to rear of tumbler.
b. Support drive guard cover and remove screws
holding guard to rear of tumbler.
Figure 12
To reduce the risk of serious injury or
death, loading door switch MUST be
reinstalled after service is completed.
W328
WARNING
SWITCH
ATTACHING
SCREWS
T315PE1A
DOOR
SWITCH
ACTUATOR
Figure 13
T210SE1A
CORNER
DRIVE
GUARD
ATTACHING
SCREW
DRIVE
GUARD
COVER