48
M413487
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
64. FAN MOTOR CONTACTOR
Refer to Figure 23.
a. Remove two attaching screws and cover from
contactor box.
b. Disconnect wires from contactor terminals.
NOTE: Refer to wiring diagram when rewiring fan
motor contactor.
c. Remove two screws holding din rail to back
wall of contactor box.
d. Slide contactor off of din rail.
65. TRANSFORMER
Refer to Figure 23.
a. Remove two attaching screws and cover from
contactor box.
b. Disconnect leads from transformer terminals.
NOTE: Refer to wiring diagram when rewiring
transformer.
c. Remove four screws holding transformer to
contactor box.
d. Remove transformer.
66. EXHAUST SYSTEM COMPONENTS
Refer to Figure 24
a. Support corner drive guard and remove screws
holding corner drive to rear of tumbler.
b. Support drive guard cover and remove screws
holding guard to rear of tumbler.
c. Remove vent pipe.
d. Remove attaching screws and thimble
assembly from duct box wrap.
e. Remove attaching screws, duct box wrap, and
damper assembly from tumbler.
Figure 24
T211SE1A
DAMPER
ASSEMBLY
DUCT BOX
WRAP
THIMBLE
ASSEMBLY
VENT
PIPE