24
M413487
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
22. PUSH-TO-START SWITCH
(Manual Timer Models)
a. Remove four screws holding access panel to
cabinet. Refer to Figure 1.
b. Lift access panel off top edge of front panel and
pull panel forward. Refer to Figure 1.
c. Remove timer box cover. Refer to Figure 1.
d. Remove two screws holding switch to timer
graphic panel. Refer to Figure 4.
e. Disconnect wires from switch terminals and
remove switch.
NOTE: Refer to wiring diagram when rewiring
switch.
23. COOLING AND DRYING RUN LIGHTS
(Manual Timer Models)
a. Remove four screws holding access panel to
cabinet. Refer to Figure 1.
b. Lift access panel off top edge of front panel and
pull panel forward. Refer to Figure 1.
c. Remove timer box cover. Refer to Figure 1.
d. Disconnect light wire leads. Refer to Figure 4.
e. Compress locking tabs on sides of light and
push light through timer graphic panel.
Figure 2
SIGNAL
BUZZER
T217SE3B
FUSE
HOLDER
NUT
IGNITION
CONTROL
NOTE:
CONTROL
BOX COVER
REMOVED.
REAR
FRONT
CONTROL BOX
COVER
TOP VIEW OF TUMBLER