22
Rockwell Automation Publication 2080-UM002K-EN-E - March 2019
Chapter 2
About Your Controller
EMC Directive
This product is tested to meet Council Directive 2014/30/EU Electromagnetic
Compatibility (EMC) Directive and the following standards, in whole or in part,
documented in a technical construction file:
•
EN 61131-2; Programmable Controllers (Clause 8, Zone A & B)
•
EN 61131-2; Programmable Controllers (Clause 11)
•
EN 61000-6-4
EMC - Part 6-4: Generic Standards - Emission Standard for Industrial
Environments
•
EN 61000-6-2
EMC - Part 6-2: Generic Standards - Immunity for Industrial
Environments
This product is intended for use in an industrial environment.
Low Voltage Directive
This product is tested to meet Council Directive 2014/35/EU Low Voltage
Directive, by applying the safety requirements of EN 61131-2 Programmable
Controllers, Part 2 - Equipment Requirements and Tests.
For specific information required by EN 61131-2, see the appropriate sections in
this publication, as well as the following Allen-Bradley publications:
•
Industrial Automation Wiring and Grounding Guidelines for Noise
Immunity
, publication
•
Guidelines for Handling Lithium Batteries
, publication AG-5.4
•
Automation Systems Catalog
, publication B115
Installation Considerations
Most applications require installation in an industrial enclosure (Pollution
Degree 2
(1)
) to reduce the effects of electrical interference (Over Voltage
Category II
(2)
) and environmental exposure.
Locate your controller as far as possible from power lines, load lines, and other
sources of electrical noise such as hard-contact switches, relays, and AC motor
drives. For more information on proper grounding guidelines, see the
Industrial
Automation Wiring and Grounding Guidelines
publication
(1) Pollution Degree 2 is an environment where normally only non-conductive pollution occurs except that
occasionally temporary conductivity caused by condensation shall be expected.
(2) Overvoltage Category II is the load level section of the electrical distribution system. At this level, transient
voltages are controlled and do not exceed the impulse voltage capability of the products insulation.
Содержание Micro830
Страница 6: ...vi Rockwell Automation Publication 2080 UM002K EN E March 2019 Preface Notes ...
Страница 24: ...10 Rockwell Automation Publication 2080 UM002K EN E March 2019 Chapter 1 Hardware Overview Notes ...
Страница 70: ...56 Rockwell Automation Publication 2080 UM002K EN E March 2019 Chapter 4 Wire Your Controller Notes ...
Страница 88: ...74 Rockwell Automation Publication 2080 UM002K EN E March 2019 Chapter 5 Communication Connections Notes ...
Страница 190: ...176 Rockwell Automation Publication 2080 UM002K EN E March 2019 Chapter 9 Controller Security Notes ...
Страница 254: ...240 Rockwell Automation Publication 2080 UM002K EN E March 2019 Appendix A Specifications Notes ...
Страница 273: ...Rockwell Automation Publication 2080 UM002K EN E March 2019 259 Quickstarts Appendix C ...
Страница 300: ...286 Rockwell Automation Publication 2080 UM002K EN E March 2019 Appendix C Quickstarts Notes ...
Страница 330: ...316 Rockwell Automation Publication 2080 UM002K EN E March 2019 Appendix E Troubleshooting Notes ...
Страница 344: ...330 Rockwell Automation Publication 2080 UM002K EN E March 2019 Appendix F PID Function Blocks Notes ...
Страница 352: ...Rockwell Automation Publication 2080 UM002K EN E March 2019 338 Index Notes ...
Страница 353: ...Rockwell Automation Publication 2080 UM002K EN E March 2019 339 ...