114
Rockwell Automation Publication 2080-UM002K-EN-E - March 2019
Chapter 7
Motion Control
Limits
Edit the Limits parameters based on the table below.
ATTENTION:
To learn more about the different types of Limits,
see
.
Limits Parameters
Parameter
(1)
(1)
To convert from user units to pulse:
Value
Hard Limits
Defines upper and lower hard limits for the axis.
When hard limits is reached, apply Configure whether to perform a forced PTO hardware stop
(immediately turn off pulse output) or whether to decelerate
(leave pulse output on and use deceleration values as
defined on the Emergency Stop profile).
Set as any of the following:
•
Forced PTO Hardware Stop
•
Emergency Stop Profile
Lower Hard Limit
Click checkbox to enable a lower hard limit.
Active Level (for Lower Hard Limit)
High or Low.
Upper Hard Limit
Click checkbox to enable.
Active Level (for Upper Hard Limit)
High or Low.
Soft Limits
Defines upper and lower soft limits values.
Lower Soft Limit
(2)
(2)
The parameter is set as REAL (float) value in Connected Components Workbench. To learn more about
conversions and rounding of REAL values, see
Real Data Resolution on page 118
Lower soft limit should be less than upper soft limit.
1. Click checkbox to enable an lower/upper soft limit.
2. Specify a value (in mm).
Upper Soft Limit
(2)
TIP
A red border on an input field indicates that an invalid value has been
entered. Scroll over the field to see tooltip message that will let you
know the valid value range for the parameter. Supply the valid value.
Value in user unit = Value in pulse x Travel per revolution
Pulse per revolution
Содержание Micro830
Страница 6: ...vi Rockwell Automation Publication 2080 UM002K EN E March 2019 Preface Notes ...
Страница 24: ...10 Rockwell Automation Publication 2080 UM002K EN E March 2019 Chapter 1 Hardware Overview Notes ...
Страница 70: ...56 Rockwell Automation Publication 2080 UM002K EN E March 2019 Chapter 4 Wire Your Controller Notes ...
Страница 88: ...74 Rockwell Automation Publication 2080 UM002K EN E March 2019 Chapter 5 Communication Connections Notes ...
Страница 190: ...176 Rockwell Automation Publication 2080 UM002K EN E March 2019 Chapter 9 Controller Security Notes ...
Страница 254: ...240 Rockwell Automation Publication 2080 UM002K EN E March 2019 Appendix A Specifications Notes ...
Страница 273: ...Rockwell Automation Publication 2080 UM002K EN E March 2019 259 Quickstarts Appendix C ...
Страница 300: ...286 Rockwell Automation Publication 2080 UM002K EN E March 2019 Appendix C Quickstarts Notes ...
Страница 330: ...316 Rockwell Automation Publication 2080 UM002K EN E March 2019 Appendix E Troubleshooting Notes ...
Страница 344: ...330 Rockwell Automation Publication 2080 UM002K EN E March 2019 Appendix F PID Function Blocks Notes ...
Страница 352: ...Rockwell Automation Publication 2080 UM002K EN E March 2019 338 Index Notes ...
Страница 353: ...Rockwell Automation Publication 2080 UM002K EN E March 2019 339 ...