Publication 1756-UM522B-EN-P - February 2003
1756-DMF30 Specific Information C-83
2086
Meter Port3 Sel
Enter a value to configure the output of the meter port.
Default:
Val 0
Zero
Options:
Val 0
Val 1
Val 2
Val 3
Val 4
Val 5
Val 6
Val 7
Val 8
Val 9
Val 10
Val 11
Val 12
Val 13
Val 14
Val 15
Val 16
Val 17
Val 18
Val 19
Val 20
Val 21
Val 22
Val 23
Val 24
Val 25
Val 26
Val 27
Val 28
Zero
3Ph I Ref Ct
3Ph I FB Ct
3Ph I Fbk A
3Ph Voltage
3Ph Max Ang
3Ph Ang
3Ph Min Ang
Fld I Ref Ct
Fld I FB Ct
Fld I FB A
Fld Voltage
Fld Max Ang
Fld Ang
Fld Min Ang
Cntr EMF V
AC Volts
User An In
Spd FB RPM
App Data
Rail Prt0 C0
Rail Prt0 C1
Rail Prt0 C2
Rail Prt0 C3
Rail Prt1 C0
Rail Prt1 C1
Rail Prt1 C2
Rail Prt1 C3
Reserved
File:
Group:
DPS/PMI
Inputs & Outputs
2087
M10v Val
Enter the value of the source parameter that correponds to
+10V dc output at the meter.
Default:
Min:
Max:
Type:
File:
Group:
0
-32768
32767
Linkable, Read-Write, 32-Bit Integer
DPS/PMI
Inputs & Outputs
2088
MeterP3 -10v Val
Enter the value of the source parameter that correponds to
-10V dc output at the meter.
Default:
Min:
Max:
Type:
File:
Group:
0
-32768
32767
Linkable, Read-Write, 32-Bit Integer
DPS/PMI
Inputs & Outputs
No.
Name
Description
Values
Содержание ControlLogix 1756-DMD30
Страница 1: ...ControlLogix Drive Module 1756 DMD30 1756 DMF30 User Manual y...
Страница 4: ......
Страница 8: ...Publication 1756 UM522B EN P February 2003 4...
Страница 10: ...Publication 1756 UM522B EN P February 2003 Summary of Changes 2 Notes...
Страница 14: ...Publication 1756 UM522B EN P February 2003 Preface 4 Notes...
Страница 26: ...Publication 1756 UM522B EN P February 2003 2 4 Drive Comm Drive Communication Notes...
Страница 44: ...Publication 1756 UM522B EN P February 2003 4 8 Installing the Drive Module Notes...
Страница 252: ...Publication 1756 UM522B EN P February 2003 B 172 1756 DMD30 Specific Information Notes...